Noncontact optical measurement of lens capsule thickness in human, monkey, and rabbit postmortem eyes
- PMID: 15851570
- DOI: 10.1167/iovs.05-0039
Noncontact optical measurement of lens capsule thickness in human, monkey, and rabbit postmortem eyes
Abstract
Purpose: To measure interspecies thickness differences in the central anterior and posterior capsules of postmortem crystalline lenses, by a technique that maintains the anatomic integrity of the lens.
Methods: Central capsule thickness was measured with a custom-built, noncontact optical system, using a focus detection technique. Anterior and posterior lens capsule thickness measurements were performed on 22 human, 29 monkey, and 34 New Zealand White rabbit intact postmortem lenses in situ. Eyes were prepared for optical measurements by bonding a PMMA ring to the sclera in the region of the ciliary body after the conjunctiva, adipose, and muscle tissues were removed. The posterior pole was removed by making a circumferential incision through the sclera approximately 7 mm posterior to the limbus. Excess vitreous was removed to expose the posterior capsule surface, and the eye assembly was placed on a Teflon slide. The cornea and iris were sectioned to expose the anterior capsule surface. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Lens capsule thickness was measured from the histologic slides and compared to the optical
Results: results. Central anterior lens capsule thickness was 8.2 +/- 5.5 (human), 7.5 +/- 4.4 (monkey), and 10.7 +/- 4.2 (rabbit) microm optically and 12.4 +/- 2.5 (human), 10.7 +/- 3.7 (monkey), and 10.4 +/- 2.0 (rabbit) microm histologically. Central posterior capsule thickness was 6.3 +/- 2.2 (human), 5.9 +/- 1.7 (monkey), and 7.8 +/- 2.3 (rabbit) microm optically and 4.1 +/- 1.5 (human), 3.5 +/- 1.6 (monkey), and 4.7 +/- 2.5 (rabbit) microm histologically.
Conclusions: The central anterior and posterior lens capsule thicknesses do not appear to vary considerably among human, rabbit, and monkey eyes. There were significant differences between optical in situ measurements and histology, which indicates that histologic preparation may affect lens capsule thickness.
Similar articles
-
Human lens capsule thickness as a function of age and location along the sagittal lens perimeter.Invest Ophthalmol Vis Sci. 2006 May;47(5):2053-60. doi: 10.1167/iovs.05-1002. Invest Ophthalmol Vis Sci. 2006. PMID: 16639015
-
Central surface curvatures of postmortem- extracted intact human crystalline lenses: implications for understanding the mechanism of accommodation.Ophthalmology. 2004 Sep;111(9):1699-704. doi: 10.1016/j.ophtha.2004.03.033. Ophthalmology. 2004. PMID: 15350325
-
[Central corneal thickness measurement by optical coherence tomography after Nd: YAG capsulotomy in patients with posterior capsule opacity].Klin Oczna. 2008;110(7-9):259-64. Klin Oczna. 2008. PMID: 19112857 Polish.
-
Atomic force microscopy measurements of lens elasticity in monkey eyes.Mol Vis. 2007 Apr 2;13:504-10. Mol Vis. 2007. PMID: 17417612 Free PMC article.
-
The lens capsule and zonulae.Acta Ophthalmol Suppl (1985). 1992;(205):7-12. doi: 10.1111/j.1755-3768.1992.tb02175.x. Acta Ophthalmol Suppl (1985). 1992. PMID: 1332416 Review.
Cited by
-
Role of the lens capsule on the mechanical accommodative response in a lens stretcher.Invest Ophthalmol Vis Sci. 2008 Oct;49(10):4490-6. doi: 10.1167/iovs.07-1647. Epub 2008 May 30. Invest Ophthalmol Vis Sci. 2008. PMID: 18515568 Free PMC article.
-
Harnessing the Underutilized Potential of Lens Capsule Transplantation in Ophthalmology: A Narrative Review of Current Applications and Future Directions.Cureus. 2025 Apr 14;17(4):e82259. doi: 10.7759/cureus.82259. eCollection 2025 Apr. Cureus. 2025. PMID: 40370915 Free PMC article. Review.
-
Contributions of mouse genetic background and age on anterior lens capsule thickness.Anat Rec (Hoboken). 2008 Dec;291(12):1619-27. doi: 10.1002/ar.20753. Anat Rec (Hoboken). 2008. PMID: 18951502 Free PMC article.
-
Lens capsule structure assessed with atomic force microscopy.Mol Vis. 2015 Mar 15;21:316-23. eCollection 2015. Mol Vis. 2015. PMID: 25814829 Free PMC article.
-
Topographical changes of biconvex objects during equatorial traction: an analogy for accommodation of the human lens.Br J Ophthalmol. 2007 Dec;91(12):1698-703. doi: 10.1136/bjo.2006.094888. Epub 2006 Jul 12. Br J Ophthalmol. 2007. PMID: 16837546 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources