Can the reading for serologic reactivity following 37 degrees C incubation be omitted?
- PMID: 1585433
- DOI: 10.1046/j.1537-2995.1992.32492263441.x
Can the reading for serologic reactivity following 37 degrees C incubation be omitted?
Abstract
The need to detect antibodies that agglutinate and/or hemolyze red cells (RBCs) directly at 37 degrees C, but do not react in subsequently performed indirect antiglobulin tests (IATs), is of concern relative to the streamlining and automation of antibody detection methods. To determine incidence and significance of such reactions, data from 87,480 tests, which used low-ionic-strength saline, 10-minute incubation at 37 degrees C, and anti-IgG, were analyzed for unexpected antibodies. There were 3590 positive tests, of which 475 showed reactions at 37 degrees C but not in subsequently performed IATs (37 + IAT-). Of these, 196 reactions were due to autoantibodies or other factors usually considered insignificant with respect to the survival of transfused incompatible RBCs, 176 were due to alloantibodies of questionable clinical significance (M, Lea, P1, etc.), and 103 were associated with alloantibodies of potential clinical significance (63 E, 27 K, 5 Jka, 4 D, 3 cE, and 1 C). This latter reaction was seen in 72 patients, with two 37 + IAT-antibodies occurring in each of 3 patients. Of the 75 potentially significant 37 + IAT-antibodies, 57 were seen in patients recently exposed to homologous RBCs, 13 in patients with a history of transfusion and/or pregnancy, and 5 in patients with no known exposure to homologous RBCs. IAT reactivity was observed in subsequent samples with 27 of these antibodies. The predictive value of a 37 + IAT-test was 21.7 percent for a potentially significant antibody. The incidence was 0.12 percent of all tests for unexpected antibodies.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Revisiting the issue: can the reading for serologic reactivity following 37 degrees C incubation be omitted?Transfusion. 1999 Mar;39(3):295-9. doi: 10.1046/j.1537-2995.1999.39399219287.x. Transfusion. 1999. PMID: 10204593
-
[Evaluation of the polyethyleneglycol antiglobulin test in the detection and identification of erythrocyte antibodies].Sangre (Barc). 1998 Feb;43(1):21-4. Sangre (Barc). 1998. PMID: 9577178 Spanish.
-
[Value of using polyethylene glycol in the indirect antiglobulin test with erythrocytes].Acta Haematol Pol. 1991;22(1):105-12. Acta Haematol Pol. 1991. PMID: 1823951 Polish.
-
The Monocyte Monolayer Assay: Past, Present and Future.Transfus Med Rev. 2019 Jan;33(1):24-28. doi: 10.1016/j.tmrv.2018.07.004. Epub 2018 Aug 8. Transfus Med Rev. 2019. PMID: 30139679 Review.
-
[Irregular agglutinins and the compatibility test: the elements of choice].Rev Fr Transfus Immunohematol. 1983 Feb;26(1):5-13. doi: 10.1016/s0338-4535(83)80045-2. Rev Fr Transfus Immunohematol. 1983. PMID: 6407087 Review. French. No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources