Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 May;79(5):1480-5.
doi: 10.1016/j.athoracsur.2004.11.058.

Aortic valve periprosthetic leakage: anatomic observations and surgical results

Affiliations

Aortic valve periprosthetic leakage: anatomic observations and surgical results

Giuseppe De Cicco et al. Ann Thorac Surg. 2005 May.

Abstract

Background: One of the most frequent causes of reoperation after heart valve replacement is periprosthetic leakage (PPL). Previous studies have failed to determine whether PPL is linked to specific anatomic details. The aim of this study was to examine the location within the aortic annulus where PPL occurs, and to evaluate the postoperative outcome after surgical correction.

Methods: Between January 1985 and December 2001, 28 patients underwent reoperation because of PPL after aortic valve replacement. The aortic annulus was analyzed in a clockwise format with hour 1 corresponding to the commissure between the left coronary sinus and the right coronary sinus, hour 5 to the commissure between the right coronary sinus and the noncoronary sinus, and hour 9 to the commissure between the noncoronary sinus and the left coronary sinus.

Results: Overall operative mortality was 7.1% (2 patients). Repair of PPL was carried out in 8 patients whereas prosthetic valve replacement was necessary in 20 patients. Urgency or emergency operation (p < 0.0037), preoperative New York Heart Association class IV (p < 0.04), need for prosthetic valve replacement (p = 0.05), and implant of mechanical valve (p = 0.031) were independent determinants of dismal prognosis. Periprosthetic leakage occurred more frequently between hour 4 and hour 8 (19 patients), with the risk of leakage being two times greater than in other annular areas.

Conclusions: Our study suggests that PPL occurs more frequently in a specific portion of the peculiar aortic annulus. In case of PPL diagnosis, a timely reoperation might decrease operative risks by avoiding emergency procedures and unfavorable preoperative clinical conditions, and preventing prosthetic valve replacement.

PubMed Disclaimer

LinkOut - more resources