. 2005 May;79(5):1536-44; discussion 1536-44.
doi: 10.1016/j.athoracsur.2004.10.041.

Minimally invasive left ventricular epicardial lead placement: surgical techniques for heart failure resynchronization therapy

Affiliations

Minimally invasive left ventricular epicardial lead placement: surgical techniques for heart failure resynchronization therapy

José L Navia et al. Ann Thorac Surg. 2005 May.

Abstract

Background: Epicardial lead placement for biventricular pacing is often a rescue procedure after failed coronary sinus cannulation. This study aims to determine perioperative and early postoperative outcome of minimally invasive left ventricular lead placement as a management strategy for heart failure, comparing minithoracotomy and endoscopic approaches.

Methods: From October 2002 through October 2003, 41 patients underwent minimally invasive left ventricular lead placement, 23 (56%) by minithoracotomy and 18 (44%) endoscopically. Thirty-one (76%) were males, 19 (46%) had previous cardiac surgery, 21 (51%) had ischemic cardiomyopathy, 17 (41%) were in New York Heart Association class III or IV, and 28 (65%) had implantable cardioverter-defibrillators.

Results: There were no in-hospital deaths, intraoperative complications, or failures to implant the left ventricular lead. Median operative time was longer for the endoscopic approach (188 minutes) than for minithoracotomy (151 minutes; p = 0.006). Preoperatively, the endoscopic group had more mitral regurgitation (median, 2.5 versus 1.0, respectively; p = 0.009). QRS duration was shorter postoperatively (mean change from preoperative, -32 +/- 24 ms; p < 0.0001); this change was unrelated to surgical approach. Impedance also was less postoperatively (mean change, -490 +/- 300 ohms; p < 0.0001), and the change was unrelated to surgical approach. Changes were greater the larger their preoperative values (p < 0.0001). Threshold increased with follow-up time (adjusted p < 0.0001), but impedance decreased (adjusted p = 0.0009); these trends were similar for both approaches. No changes were evident in left ventricular dimensions.

Conclusions: Minimally invasive left ventricular epicardial lead placement is safe and effective, offering selection of the best pacing site with minimal morbidity; it can be considered a primary option for resynchronization therapy.