Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Apr;15(4):211-4.

Comparison of fine needle aspiration cytology with excision biopsy of breast lump

Affiliations
  • PMID: 15857592
Comparative Study

Comparison of fine needle aspiration cytology with excision biopsy of breast lump

Mirza Tassawar Hussain. J Coll Physicians Surg Pak. 2005 Apr.

Abstract

Objective: To evaluate the results of fine needle aspiration cytology (FNAC) of breast lump by histopathology of excision biopsy specimen in the same group of patients.

Design: A descriptive study.

Place and duration of study: Department of Surgery, Federal Government Services Hospital, Islamabad from October, 2000 to March, 2001.

Materials and methods: There were 50 patients in the study, who were subjected to fine needle aspiration cytology with a needle of 22G mounted on 20 cc syringe. Smears were fixed on the slides with 95% alcohol and later stained with hematoxylin and eosin stain. After FNAC, all the patients were subjected to excision biopsy. The specimen were reported by the Histopathologist and results evaluated and compared.

Results: All patients were among the total number of 61 FNAC performed, conclusive malignancy (C5) was found in 20(40%) patients and in 1(2%) patient, malignancy was suspected (C4). Conclusive benign lesions (C2) were found in 26(52%) patients and 2 patients had atypia i.e. (C3). Inadequate specimen (C1) was found in 2(4%) patients. On excision biopsy, 22(44%) patients had malignant lumps and 28(56%) benign. FNAC was able to detect 20 malignant lumps with sensitivity of 90.90%. All of them were also reported malignant on excision biopsy with specificity of 100%. False positive were zero and false negative were 9.1%.

Conclusion: FNAC is simple, quick, safe, tolerable, cosmetically acceptable, reliable and cost-effective method of determining histology of breast lumps. The absence of false positives conclusively confirmed its place not only as a complimentary adjunct but also a substitute of excision biopsy in majority of instances.

PubMed Disclaimer

Similar articles

Cited by

Publication types