Nebulizer function during mechanical ventilation
- PMID: 1586056
- DOI: 10.1164/ajrccm/145.5.1117
Nebulizer function during mechanical ventilation
Abstract
In the setting of mechanical ventilation, recent studies have cast doubt on the ability of nebulizer systems to deliver adequate amounts of medication. We therefore studied ventilator-related and nebulizer-related factors that could potentially affect the amount of aerosol inhaled by an intubated subject. Utilizing two separate protocols, we used a bench model of a ventilator circuit, radiolabeled (technetium pertechnetate, 99mTc) saline droplets and a filter technique to measure the percentage of radioaerosol delivered. First, we compared four commercially available jet nebulizers and found that there were significant differences in rate of aerosol production between systems, ranging from 3 to 37%. Delivered aerosol was measured at different ventilator settings, and it was found that the duty cycle can potentially influence output by sevenfold. Some nebulizers were also sensitive to changes in the initial volume of solution placed in the nebulizer. The inclusion of a humidification device significantly reduced output by a mean of 41 +/- 3.5%, but it did not affect particle distribution. Endotracheal tube diameter was not an important variable. Then, with the effects of the above variables established, a separate series of experiments was performed to test whether the use of different radiolabeling compounds can confound the measurement of inhaled drugs. Two nebulizers (AeroTech II and Twin Jet) and pentamidine as the test drug were studied with fixed ventilator settings, treatment time, endotracheal tube size, and volume fill. No humidification was used. The nebulizer solution was labeled with 99mTc, which was bound to either human serum albumin (HSA) or sulfur colloid (SC).(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Aerosol deposition in mechanically ventilated patients. Optimizing nebulizer delivery.Am J Respir Crit Care Med. 1994 Jan;149(1):214-9. doi: 10.1164/ajrccm.149.1.8111585. Am J Respir Crit Care Med. 1994. PMID: 8111585
-
Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill.Am Rev Respir Dis. 1992 Aug;146(2):383-8. doi: 10.1164/ajrccm/146.2.383. Am Rev Respir Dis. 1992. PMID: 1489128
-
Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.Eur Respir J. 1997 Apr;10(4):905-9. Eur Respir J. 1997. PMID: 9150333 Clinical Trial.
-
Special problems in aerosol delivery: artificial airways.Respir Care. 2000 Jun;45(6):636-45. Respir Care. 2000. PMID: 10894456 Review.
-
Design principles of liquid nebulization devices currently in use.Respir Care. 2002 Nov;47(11):1257-75; discussion 1275-8. Respir Care. 2002. PMID: 12425742 Review.
Cited by
-
Pulmonary deposition of a nebulised aerosol during mechanical ventilation.Thorax. 1993 Feb;48(2):154-9. doi: 10.1136/thx.48.2.154. Thorax. 1993. PMID: 8493630 Free PMC article.
-
Prostacyclin aerosol in an infant with pulmonary hypertension.Eur J Pediatr. 1995 Mar;154(3):233-5. doi: 10.1007/BF01954279. Eur J Pediatr. 1995. PMID: 7758525
-
Two administration methods for inhaled salbutamol in intubated patients.Arch Dis Child. 2002 Jul;87(1):49-53. doi: 10.1136/adc.87.1.49. Arch Dis Child. 2002. PMID: 12089124 Free PMC article. Clinical Trial.
-
Aerosolised antibacterials for the prevention and treatment of hospital-acquired pneumonia.Drugs. 2007;67(6):903-14. doi: 10.2165/00003495-200767060-00006. Drugs. 2007. PMID: 17428107 Review.
-
Effect of nebulized eucalyptus on contamination of microbial plaque of endotracheal tube in ventilated patients.Iran J Nurs Midwifery Res. 2016 Mar-Apr;21(2):165-70. doi: 10.4103/1735-9066.178242. Iran J Nurs Midwifery Res. 2016. PMID: 27095990 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous