. 2005 May;60(5):383-8.
doi: 10.1136/thx.2004.031104.

Exhaled nitric oxide in the diagnosis of asthma: comparison with bronchial provocation tests

Affiliations
Comparative Study

Exhaled nitric oxide in the diagnosis of asthma: comparison with bronchial provocation tests

N Berkman et al. Thorax. 2005 May.

Abstract

Background: Bronchial provocation tests such as exercise, methacholine (MCH), and adenosine-5'-monophosphate (AMP) challenges are used extensively in the diagnosis of asthma. A study was undertaken to determine whether exhaled nitric oxide (eNO) can be used to diagnose asthma in patients with non-specific respiratory symptoms and to compare this test with conventional provocation tests.

Methods: Patients with non-specific respiratory symptoms and normal spirometric parameters were included in the study. eNO was measured and exercise, MCH and AMP challenges performed in all subjects. Patients were defined as asthmatic based on clinical follow up 24 months after testing.

Results: Forty patients were considered asthmatic and 45 were not. The area under receiver operating characteristic curves gave values of 0.896 for eNO, 0.781 for exercise, 0.924 for MCH, and 0.939 for AMP (p = 0.033, 0.575 and 0.085 for eNO v exercise, MCH and AMP respectively). From our data, a cut off value of NO > 7 ppb at a flow rate of 250 ml/s best differentiates between asthmatics and non-asthmatics (sensitivity 82.5%, specificity 88.9%). Optimal cut off values for other tests were exercise: deltaFEV1 > or = 10% (sensitivity 57.9%, specificity 100%); PC20-MCH: < or = 3 mg/ml (sensitivity 87.5%, specificity 86.7%); and PC20-AMP: < or = 150 mg/ml (sensitivity 89.5%, specificity 95.6%).

Conclusions: Measurement of eNO can be used as a safe, simple and rapid test for the diagnosis of asthma and is as good as bronchial provocation tests.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eur Respir J. 1999 Sep;14(3):659-68 - PubMed
    1. Thorax. 1999 May;54(5):403-8 - PubMed
    1. Thorax. 2000 Mar;55(3):184-8 - PubMed
    1. Pediatr Pulmonol. 2000 Sep;30(3):207-14 - PubMed
    1. Am J Respir Crit Care Med. 2002 Jun 15;165(12):1597-601 - PubMed

Publication types