Vascular complications following intra-aortic balloon pump insertion
- PMID: 1586081
Vascular complications following intra-aortic balloon pump insertion
Abstract
The intra-aortic balloon pump (IABP) has been used for 23 years to treat cardiogenic shock from various causes. A retrospective review was conducted to evaluate the morbidity, mortality, and risk factors associated with insertion of this device. Over a recent 3-year period, 415 such pumps were inserted either by percutaneous (323) or cut-down (92) technique in 404 patients. Indications for placement included intraoperative pump failure (46%), cardiac instability before coronary artery bypass grafting (28%), perioperative support (13%), cardiac transplantation (7%), and cardiogenic shock (6%). Noncardiac vascular complications occurred in 67 patients, 55 per cent of whom required surgical correction. Operative procedures included femoral artery thrombectomy, bypass grafting, fasciotomy, and amputation. Major risk factors for vascular complications included diminished or absent femoral pulses on initial examination, being a woman, and obesity. In patients with known peripheral vascular disease, the risk of a vascular complication was 17.9 per cent when a surgical cut-down technique was used to insert the IABP, and 38.9 per cent when a percutaneous insertion was performed. The mortality doubled in those patients who had a vascular complication as compared to those who did not (34% vs 17%). A more liberal use of an open surgical technique in those patients with peripheral vascular disease, obesity, and who are women may help to reduce complications after the insertion of the intra-aortic balloon pump.
Similar articles
-
Vascular complications of the intra-aortic balloon pump: an analysis of 436 patients.Am Surg. 1993 Sep;59(9):564-8. Am Surg. 1993. PMID: 8368661
-
Iatrogenic vascular trauma associated with intra-aortic balloon pumping: identification of risk factors.Am Surg. 1993 Dec;59(12):813-7. Am Surg. 1993. PMID: 8256934
-
Recent clinical experience with percutaneous intra-aortic balloon pumping.Life Support Syst. 1986 Jul-Sep;4(3):249-56. Life Support Syst. 1986. PMID: 3491250
-
30 years clinical intra-aortic balloon pumping: facts and figures.Thorac Cardiovasc Surg. 1999 Feb;47 Suppl 2:298-303. doi: 10.1055/s-2007-1012052. Thorac Cardiovasc Surg. 1999. PMID: 10218604 Review.
-
Percutaneous intra-aortic balloon counterpulsation.Crit Care Clin. 1992 Oct;8(4):819-37. Crit Care Clin. 1992. PMID: 1393753 Review.
Cited by
-
[Peripheral arterial complications after heart catheterization].Herz. 1998 Feb;23(1):4-20. doi: 10.1007/BF03043007. Herz. 1998. PMID: 9541843 Review. German.
-
Intra-Aortic Balloon Pump Entrapment in a Nonatherosclerotic Common Iliac Artery.Open J Cardiovasc Surg. 2011 Sep 19;4:5-7. doi: 10.4137/OJCS.S7688. eCollection 2011. Open J Cardiovasc Surg. 2011. PMID: 26949336 Free PMC article.
-
Intra-aortic balloon pump: indications and complications.J Natl Med Assoc. 1998 Mar;90(3):137-40. J Natl Med Assoc. 1998. PMID: 9549976 Free PMC article.
-
Utilization of low-profile intra-aortic balloon catheters inserted by the sheathless technique in acute cardiac patients: clinical efficacy with a very low complication rate.Clin Cardiol. 2004 Nov;27(11):600-4. doi: 10.1002/clc.4960271104. Clin Cardiol. 2004. PMID: 15562927 Free PMC article.
-