Breath sound changes associated with malpositioned endotracheal tubes
- PMID: 15865129
- DOI: 10.1007/BF02345956
Breath sound changes associated with malpositioned endotracheal tubes
Abstract
Endotracheal tubes (ETTs) are used to establish airway access in patients with ventilatory failure and during general anaesthesia. Tube malpositioning can compromise respiratory function and can be associated with increased morbidity and mortality. Clinical assessment of ETT position normally involves chest auscultation, which is highly skill-dependent and can be misleading. The objective of this pilot study was to investigate breath sound changes associated with ETT malpositioning. Breath sounds were acquired in six human subjects over each hemithorax and over the epigastrium for tracheal, bronchial and oesophageal intubations. When the ETT was in the oesophagus, the acoustic energy ratio between epigastrium and chest surface increased in all subjects (p < 0.04). In addition, ETT placement in the right mainstem bronchus decreased the acoustic energy ratio between the left and right hemithoraxes in all subjects (p < 0.04). A baseline measurement of this energy ratio was needed for bronchial intubation identification. However, using this ratio after bandpass filtering (200-500 Hz) did not require a baseline value, which would increase the utility of this method for initial ETT placement. These results suggest that computerised analysis of breath sounds may be useful for assessment of ETT positioning. More studies are needed to test the feasibility of this approach further.
Similar articles
-
Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes.Anesth Analg. 2005 Sep;101(3):735-739. doi: 10.1213/01.ane.0000167068.71601.e4. Anesth Analg. 2005. PMID: 16115984
-
A visual stethoscope to detect the position of the tracheal tube.Anesth Analg. 2009 Dec;109(6):1836-42. doi: 10.1213/ANE.0b013e3181bb4967. Anesth Analg. 2009. PMID: 19923511
-
Detection of oesophageal intubations using cuff pressures in a pig trachea oesophagus model.Br J Anaesth. 2007 Nov;99(5):740-3. doi: 10.1093/bja/aem244. Epub 2007 Aug 21. Br J Anaesth. 2007. PMID: 17715140
-
Question 2. Should carbon dioxide detectors be used to check correct placement of endotracheal tubes in preterm and term neonates?Arch Dis Child. 2011 Dec;96(12):1201-3. doi: 10.1136/archdischild-2011-300893. Arch Dis Child. 2011. PMID: 22080462 Free PMC article. Review. No abstract available.
-
Cuffed versus uncuffed endotracheal tubes in children: a meta-analysis.J Anesth. 2016 Feb;30(1):3-11. doi: 10.1007/s00540-015-2062-4. Epub 2015 Aug 22. J Anesth. 2016. PMID: 26296534 Review.
Cited by
-
Inadvertent Endobronchial Intubation in a Patient With a Short Neck Length.Anesth Prog. 2015 Summer;62(2):66-70. doi: 10.2344/0003-3006-62.1.66. Anesth Prog. 2015. PMID: 26061576 Free PMC article.
-
Ideal Length of Oral Endotracheal Tube for Critically Ill Intubated Patients in an Asian Population: Comparison to Current Western Standards.Cureus. 2018 Nov 14;10(11):e3590. doi: 10.7759/cureus.3590. Cureus. 2018. PMID: 30675445 Free PMC article.
-
Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial.Front Med (Lausanne). 2022 Feb 21;9:851395. doi: 10.3389/fmed.2022.851395. eCollection 2022. Front Med (Lausanne). 2022. PMID: 35265648 Free PMC article.
-
Unexpected Lung Collapse Following Chest Tube Insertion for Pneumothorax Drainage in an Intubated Patient Due to Dislocation of the Endotracheal Tube.Cureus. 2024 Feb 29;16(2):e55236. doi: 10.7759/cureus.55236. eCollection 2024 Feb. Cureus. 2024. PMID: 38558624 Free PMC article.
-
Optimising endotracheal length in adult cats: a retrospective CT study.J Feline Med Surg. 2022 Aug;24(8):794-799. doi: 10.1177/1098612X211052214. Epub 2021 Oct 19. J Feline Med Surg. 2022. PMID: 34663125 Free PMC article.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Medical