Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 May;43(5):2231-5.
doi: 10.1128/JCM.43.5.2231-2235.2005.

Evaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples

Affiliations
Comparative Study

Evaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples

C H E Boel et al. J Clin Microbiol. 2005 May.

Abstract

Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), 229 (30%) were confirmed positive; 13 of these (5.7%) were lacking the cppB gene. Of the 534 samples (70%) that could not be confirmed, 81 (15%) showed a positive crossing point. However, melting curve analysis revealed an aberrant melting temperature in the LightCycler 16S rRNA assay; therefore, these samples were considered non-N. gonorrhoeae Neisseria species. Both of the 16S rRNA assays performed well, with positive predictive values of 99.1% and 100% for the PCR-EIAs and the real-time assays, respectively, and a negative predictive value of 99.8% for both. The cppB assays were compromised by the absence of the cppB gene in 5.7% of the N. gonorrhoeae-positive samples, resulting in negative predictive values of 96.8% and 97.6% for the PCR-EIAs and the real-time assays, respectively. Therefore, the 16S rRNA gene is preferable to the cppB gene as a target for confirmation assays. The melting curve analysis of the real-time assays provides useful additional information.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Boom, R., C. J. Sol, M. M. Salimans, C. L. Jansen, P. M. Wertheim-van Dillen, and J. van der Noordaa. 1990. Rapid and simple method for purification of nucleic acids. J. Clin. Microbiol. 28:495-503. - PMC - PubMed
    1. Bruisten, S. M., G. T. Noordhoek, A. J. C. van den Brule, B. Duim, C. H. E. Boel, K. El-Faouzi, R. du Maine, S. Mulder, D. Luijt, and J. Schirm. 2004. Multicenter validation of the cppB gene as a PCR target for detection of Neisseria gonorrhoeae. J. Clin. Microbiol. 42:4332-4334. - PMC - PubMed
    1. Centers for Disease Control and Prevention. 2002. Screening tests to detect Chlamydia trachomatis and Neisseria gonorrhoeae infections. Morb. Mortal. Wkly. Rep. 51:1-39. - PubMed
    1. Ching, S., H. Lee, E. W. Hook III, M. R. Jacobs, and J. Zenilman. 1995. Ligase chain reaction for detection of Neisseria gonorrhoeae in urogenital swabs. J. Clin. Microbiol. 33:3111-3114. - PMC - PubMed
    1. Crotchfelt, K. A., L. E. Welsh, D. DeBonville, M. Rosenstraus, and T. C. Quinn. 1997. Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in genitourinary specimens from men and women by a coamplification PCR assay. J. Clin. Microbiol. 35:1536. - PMC - PubMed

Publication types

MeSH terms