Transscleral implantation and neurophysiological testing of subretinal polyimide film electrodes in the domestic pig in visual prosthesis development
- PMID: 15876656
- DOI: 10.1088/1741-2560/2/1/008
Transscleral implantation and neurophysiological testing of subretinal polyimide film electrodes in the domestic pig in visual prosthesis development
Abstract
Loss of photoreceptor function is responsible for a variety of blinding diseases, including retinitis pigmentosa. Advances in microtechnology have led to the development of electronic visual prostheses which are currently under investigation for the treatment of human blindness. The design of a subretinal prosthesis requires that the stimulation device should be implantable in the subretinal space of the eye. Current limitations in eye surgery have to be overcome to demonstrate the feasibility of this approach and to determine basic stimulation parameters. Therefore, polyimide film-bound electrodes were implanted in the subretinal space in anaesthetized domestic pigs as a prelude to electrical stimulation in acute experiments. Eight eyes underwent surgery to demonstrate the transscleral implantability of the device. Four of the eight eyes were stimulated electrically. In these four animals the cranium was prepared for epidural recording of evoked visual cortex responses, and stimulation was performed with sequences of current impulses. All eight subretinal implantation procedures were carried out successfully with polyimide film electrodes and each electrode was implanted beneath the outer retina of the posterior pole of the operated eyes. Four eyes were used for neurophysiological testing, involving recordings of epidural cortical responses to light and electrical stimulation. A light stimulus response, which occurred 40 ms after stimulation, proved the integrity of the operated eye. The electrical stimuli occurred about 20 ms after the onset of stimulation. The stimulation threshold was approximately 100 microA. Both the threshold and the cortical responses depended on the correspondence between retinal stimulation and cortical recording sites and on the number of stimulation electrodes used simultaneously. The subretinal implantation of complex stimulation devices using the transscleral procedure with consecutive subretinal stimulation is feasible in acute experiments in an animal model approximating to the situation in humans. The domestic pig is an appropriate animal model for basic testing of subretinal implants. Animal experiments with chronically implanted devices and long-term stimulation are advisable to prepare the field for successful human experiments.
Similar articles
-
Implantation and testing of subretinal film electrodes in domestic pigs.Exp Eye Res. 2006 Feb;82(2):332-40. doi: 10.1016/j.exer.2005.07.007. Epub 2005 Aug 25. Exp Eye Res. 2006. PMID: 16125172
-
Subretinal implantation and testing of polyimide film electrodes in cats.Graefes Arch Clin Exp Ophthalmol. 2005 May;243(5):464-8. doi: 10.1007/s00417-004-1049-x. Epub 2004 Dec 1. Graefes Arch Clin Exp Ophthalmol. 2005. PMID: 15578200
-
Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit.J Neural Eng. 2005 Mar;2(1):S48-56. doi: 10.1088/1741-2560/2/1/007. Epub 2005 Feb 22. J Neural Eng. 2005. PMID: 15876654
-
Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis.Prog Brain Res. 2009;175:317-32. doi: 10.1016/S0079-6123(09)17522-2. Prog Brain Res. 2009. PMID: 19660665 Review.
-
[Research progress of subretinal implant based on electronic stimulation].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008 Feb;25(1):212-4, 219. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008. PMID: 18435293 Review. Chinese.
Cited by
-
Compound subretinal prostheses with extra-ocular parts designed for human trials: successful long-term implantation in pigs.Graefes Arch Clin Exp Ophthalmol. 2007 Feb;245(2):230-41. doi: 10.1007/s00417-006-0339-x. Graefes Arch Clin Exp Ophthalmol. 2007. PMID: 16645861
-
Subretinal electronic chips allow blind patients to read letters and combine them to words.Proc Biol Sci. 2011 May 22;278(1711):1489-97. doi: 10.1098/rspb.2010.1747. Epub 2010 Nov 3. Proc Biol Sci. 2011. PMID: 21047851 Free PMC article.
-
Modeling the response of ON and OFF retinal bipolar cells during electric stimulation.Vision Res. 2015 Jun;111(Pt B):170-81. doi: 10.1016/j.visres.2014.12.002. Epub 2014 Dec 11. Vision Res. 2015. PMID: 25499837 Free PMC article.
-
Retinal ganglion cell activity from the multifocal electroretinogram in pig: optic nerve section, anaesthesia and intravitreal tetrodotoxin.J Physiol. 2006 Jan 15;570(Pt 2):325-38. doi: 10.1113/jphysiol.2005.098046. Epub 2005 Nov 10. J Physiol. 2006. PMID: 16284074 Free PMC article.
-
Emerging synergy between nanotechnology and implantable biosensors: a review.Biosens Bioelectron. 2010 Mar 15;25(7):1553-65. doi: 10.1016/j.bios.2009.12.001. Epub 2009 Dec 11. Biosens Bioelectron. 2010. PMID: 20042326 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources