Blood component collection by apheresis
- PMID: 15880369
- DOI: 10.1002/jca.20043
Blood component collection by apheresis
Abstract
Apheresis component collection is a rapidly growing area in the blood collection field. Several instruments with varying capabilities are available. This is a brief review of the equipment available for granulocyte and apheresis component collection and indications for their use. In the United States, granulocytes are collected with the Fenwal CS3000, Fenwal CS3000 Plus, COBE (Gambro) Spectra, Haemonetics LN9000, and Fresenius AS 104. The use of hetastarch for sedimenting agent and stimulation with G-CSF and G-CSF plus dexamethasone have substantially increased granulocyte yields. Plateletapheresis is performed in the United States on the Fenwal CS3000, Fenwal CS3000 Plus, Fenwal Amicus, COBE (Gambro) Spectra, Gambro Trima Version 4, Gambro Trima Accel (Version 5), and Haemonetics LN9000. Automated red blood cell (RBC) collections are performed with the Haemonetics MCS+LN8150, Gambro Trima Version 4, Gambro Trima Accel (Version 5), Amicus, and Baxter Alyx. The RBC can be collected concurrently (with other components) in some instruments or separately in others. Plasma is collected concurrently on several instruments. Plasmapheresis for plasma only is performed on the Fenwal Autopheresis C and Haemonetics PCS2. Granulocyte yields range from 0.46 x 10(10) to 1.0 x 10(10) for unstimulated donors and 2.1 x 10(10) to 2.6 x 10(10) for donors stimulated with dexamethasone or prednisone. The use of G-CSF and G-CSF with dexamethasone has substantially increased granulocyte yields with yields of 4.1 x 10(10) to 10.8 x 10(10) reported. Platelet collection rates of 0.045-0.115 x 10(11) plt/min have been reported. Collection efficiencies of 46-85.7% have been reported. Automated (apheresis) component collection has the advantages of controlled volumes or doses of component, efficient use of the donor, multiple components from the same donor, better inventory control, and better quality control due to less manipulation of the individual components. Disadvantages of automated component collection include the use of expensive equipment and disposables, the need for specially trained machine operators, and lower capacity to collect large volumes of blood compared to whole blood donation. The use of apheresis component collection is rapidly growing to provide the best blood components in the most efficient manner.
Similar articles
-
Prospective comparison of high-dose plateletpheresis with the latest apheresis systems on the same donors.Transfusion. 2006 Sep;46(9):1601-8. doi: 10.1111/j.1537-2995.2006.00928.x. Transfusion. 2006. PMID: 16965590
-
Prospective evaluation of double RBC collection using three different apheresis systems.Transfus Apher Sci. 2006 Dec;35(3):197-205. doi: 10.1016/j.transci.2006.08.004. Epub 2006 Nov 9. Transfus Apher Sci. 2006. PMID: 17097350 Clinical Trial.
-
Frequently used plateletpheresis techniques result in variable target yields and platelet recruitment of donors.Transfusion. 2005 May;45(5):788-97. doi: 10.1111/j.1537-2995.2005.04353.x. Transfusion. 2005. PMID: 15847670
-
Safety of donating multiple products in a single apheresis collection: are we expecting too much?J Clin Apher. 2003;18(3):135-40. doi: 10.1002/jca.10069. J Clin Apher. 2003. PMID: 14569607 Review.
-
Plateletpheresis: what's new?Transfus Sci. 1996 Dec;17(4):537-44. Transfus Sci. 1996. PMID: 10168551 Review.
Cited by
-
Aggregates in blood filter chambers used from the plasma donations of anti-D donors: evaluation for monoclonal antibody discovery using phage display.Blood Transfus. 2021 Jan;19(1):64-72. doi: 10.2450/2020.0093-20. Epub 2020 Oct 9. Blood Transfus. 2021. PMID: 33085594 Free PMC article.
-
Reply to Farrugia: Appropriately specifying the quality of plasma for fractionation.Vox Sang. 2022 Mar;117(3):460-461. doi: 10.1111/vox.13185. Epub 2021 Jul 30. Vox Sang. 2022. PMID: 34327713 Free PMC article. No abstract available.
-
Mass-tag barcoding for multiplexed analysis of human synaptosomes and other anuclear events.Cytometry A. 2021 Sep;99(9):939-945. doi: 10.1002/cyto.a.24340. Epub 2021 Apr 5. Cytometry A. 2021. PMID: 33818911 Free PMC article.
-
Successful autologous peripheral blood stem cell transplantation in a Jehovah's Witness with multiple myeloma: review of literature and recommendations for high-dose chemotherapy without support of allogeneic blood products.Int J Hematol. 2008 Apr;87(3):289-97. doi: 10.1007/s12185-008-0055-x. Epub 2008 Mar 4. Int J Hematol. 2008. PMID: 18317881 Review.
-
Exploratory studies of extended storage of apheresis platelets in a platelet additive solution (PAS).Blood. 2014 Jan 9;123(2):271-80. doi: 10.1182/blood-2013-05-501247. Epub 2013 Nov 20. Blood. 2014. PMID: 24258816 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials