Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Apr 22;1072(1):37-43.
doi: 10.1016/j.chroma.2004.10.066.

Membrane-assisted solvent extraction of seven phenols combined with large volume injection-gas chromatography-mass spectrometric detection

Affiliations

Membrane-assisted solvent extraction of seven phenols combined with large volume injection-gas chromatography-mass spectrometric detection

Manuela Schellin et al. J Chromatogr A. .

Abstract

Membrane-assisted solvent extraction (MASE) was applied for the determination of seven phenols (phenol, 2-chlorophenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 4-chloro-3-methylphenol, 2,4,6-trichlorophenol and pentachlorophenol) with log Kow (octanol-water-partition-coefficient) between 1.46 (phenol) and 5.12 (pentachlorophenol) in water. The extraction solvents cyclohexane, ethyl acetate and chloroform were tested and ethyl acetate proved to be the best choice. The optimisation of extraction conditions showed the necessity of adding 5 g of sodium chloride to each aqueous sample to give a saturated solution (333 g/L). The pH-value of the sample was adjusted to 2 in order to convert all compounds into their neutral form. An extraction time of 60 min was found to be optimal. Under these conditions the recovery of phenol, the most polar compound, was 11%. The recoveries of the other analytes ranged between 42% (2-chlorophenol) and 98% (2,4-dichlorophenol). Calibration was performed using large volume injection (100 microL injection volume). At optimised conditions the limits of detection were between 0.01 and 0.6 microg/L and the relative standard deviation (n = 3) was on average about 10%. After the method optimisation with reagent water membrane-assisted solvent extraction was applied to two contaminated ground water samples from the region of Bitterfeld in Saxony-Anhalt, Germany. The results demonstrate the good applicability of membrane-assisted solvent extraction for polar analytes like phenols, without the necessity of derivatisation or a difficult and time-consuming sample preparation.

PubMed Disclaimer

MeSH terms

LinkOut - more resources