. 1992 Jan;9(1):119-25.
doi: 10.1023/a:1018948314823.

Validation of a column-switching high-performance liquid chromatographic (HPLC) method for determination of ML-1035 and its five metabolites in plasma

Affiliations

Validation of a column-switching high-performance liquid chromatographic (HPLC) method for determination of ML-1035 and its five metabolites in plasma

B S Kuo et al. Pharm Res. 1992 Jan.

Abstract

A fully automated column-switching HPLC procedure has been developed and validated for quantitation of ML-1035 and its five metabolites in plasma employing direct injection. Plasma samples were injected onto a CN extraction column (4 x 4.6 mm, 5 microns) for micellar cleanup with 0.5% sodium dodecyl sulfate (SDS) in 50 mM phosphate. The proteinaceous components were solubilized and flushed out. The extracted compounds were then eluted by forward flush onto a C8 analytical column (150 x 4.6 mm, 5 microns) for further analysis using fluorescence detection (excitation, 308 nm; emission, 350 nm). After the subsequent washing and reequilibration with a sequence of three solvent mixtures, the extraction column was ready for the next injection. The limit of quantitation for all compounds of interest was about 10 to 15 ng/ml using 100 microliters of plasma. Excellent precision, accuracy, and linearity were obtained for all compounds over a range of 10 to 1500 ng/ml. The practicality of the HPLC method was also validated with plasma samples from dogs receiving ML-1035. Longevity for both extraction and analytical columns is excellent. Micellar cleanup coupled with the column-switching technique is a promising HPLC procedure when using direct injection of biological fluids.