Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives

Affiliations
Review

Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives

Songmei Gao et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

High performance liquid chromatography with atmospheric pressure ionization (API) mass spectrometry has been essential to a large number of quantitative analytical applications for a variety of compounds. Poor detection sensitivity however is a problem observed for a number of analytes because detection sensitivity can be affected by many factors. The two most critical factors are the chemical and physical properties of the analyte and the composition of the mobile phase. In order to address these critical factors which may lead to poor sensitivity, either the structure of the analyte must be modified or the mobile phase composition optimized. The introduction of permanently charged moieties or readily ionized species may dramatically improve the ionization efficiency for electrospray ionization (ESI), and thus the sensitivity of detection. Detection sensitivity may also be enhanced via introduction of moieties with high proton affinity or electron affinity. Mobile phase component modification is an alternative way to enhance sensitivity by changing the form of the analytes in solution thereby improving ionization efficiency. pH adjustment and adduct formation have been commonly used to optimize detection conditions. The sensitivity of detection for analytes in bio-matrices could also be enhanced by decreasing ion-suppression from the matrix through derivatization or mobile phase addition. In this review, we will discuss detection-oriented derivatization as well as the application of mobile phase additives to enhance the sensitivity of detection in liquid chromatograph/atmospheric ionization/mass spectrometry (LC/API/MS), focusing in particular on the applications involving small molecules in bio-matrices.