Intermittent micromotion inhibits bone ingrowth. Titanium implants in rabbits
- PMID: 1590046
- DOI: 10.3109/17453679209154809
Intermittent micromotion inhibits bone ingrowth. Titanium implants in rabbits
Abstract
We studied the effects of micromotion on bone ingrowth into a 1-mm canal through a titanium chamber implanted in the proximal tibia of rabbits. The implant surface became "osseointegrated," but an interior core was movable, allowing the central portion of the canal to be moved in relation to the ends. Thus, the ingrowing bone in the canal had to pass an area of ad latus motion. When implanted in rabbit tibiae, the canal became filled with ingrown cancellous bone. Bone ingrowth was inhibited by 20 cycles of 0.5-mm movement applied during a 30-second period once daily. With this regimen, the canal was usually filled with vascularized fibrous tissue and significantly less bone. The micromotion chamber may enable detailed studies of the effects of different motion variables on ingrowth of bone.
Similar articles
-
Effect of amplitude of micromotion on bone ingrowth into titanium chambers implanted in the rabbit tibia.Biomaterials. 1992;13(13):944-8. doi: 10.1016/0142-9612(92)90118-8. Biomaterials. 1992. PMID: 1477264
-
Difference in bone ingrowth after one versus two daily episodes of micromotion: experiments with titanium chambers in rabbits.J Biomed Mater Res. 1993 Nov;27(11):1419-24. doi: 10.1002/jbm.820271109. J Biomed Mater Res. 1993. PMID: 8263004
-
Ingrowth of bone into pores in titanium chambers implanted in rabbits: effect of pore cross-sectional shape in the presence of dynamic shear.J Biomed Mater Res. 1993 Feb;27(2):247-53. doi: 10.1002/jbm.820270215. J Biomed Mater Res. 1993. PMID: 8436582
-
Intermittent micromotion and polyethylene particles inhibit bone ingrowth into titanium chambers in rabbits.J Appl Biomater. 1995 Fall;6(3):161-5. doi: 10.1002/jab.770060303. J Appl Biomater. 1995. PMID: 7492805
-
Implant fixation by bone ingrowth.J Arthroplasty. 1999 Apr;14(3):355-68. doi: 10.1016/s0883-5403(99)90063-3. J Arthroplasty. 1999. PMID: 10220191 Review.
Cited by
-
Glass-ceramic-coated titanium hip endoprosthesis. Experimental study in rabbits.Arch Orthop Trauma Surg. 1995;114(2):119-22. doi: 10.1007/BF00422839. Arch Orthop Trauma Surg. 1995. PMID: 7734233
-
The Effects of Interlocking a Universal Hip Cementless Stem on Implant Subsidence and Mechanical Properties of Cadaveric Canine Femora.Vet Surg. 2016 Feb;45(2):155-64. doi: 10.1111/vsu.12437. Epub 2016 Jan 15. Vet Surg. 2016. PMID: 26767439 Free PMC article.
-
Bone healing in porous implants: a histological and histometrical comparative study on sheep.J Mater Sci Mater Med. 2000 Nov;11(11):711-7. doi: 10.1023/a:1008971611885. J Mater Sci Mater Med. 2000. PMID: 15348077
-
Design, Modeling, and Evaluation of the Eddy Current Sensor Deeply Implanted in the Human Body.Sensors (Basel). 2018 Nov 11;18(11):3888. doi: 10.3390/s18113888. Sensors (Basel). 2018. PMID: 30423900 Free PMC article.
-
Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric study in German Shepherd.Iran J Vet Res. 2023;24(3):242-246. doi: 10.22099/IJVR.2023.47029.6770. Iran J Vet Res. 2023. PMID: 38269008 Free PMC article.