Catheterization-Doppler discrepancies in nonsimultaneous evaluations of aortic stenosis
- PMID: 15901286
- DOI: 10.1111/j.1540-8175.2005.04006.x
Catheterization-Doppler discrepancies in nonsimultaneous evaluations of aortic stenosis
Abstract
Prior validation studies have established that simultaneously measured catheter (cath) and Doppler mean pressure gradients (MPG) correlate closely in evaluation of aortic stenosis (AS). In clinical practice, however, cath and Doppler are rarely performed simultaneously; which may lead to discrepant results. Accordingly, our aim was to ascertain agreement between these methods and investigate factors associated with discrepant results. We reviewed findings in 100 consecutive evaluations for AS performed in 97 patients (mean age 72 +/- 10 yr) in which cath and Doppler were performed within 6 weeks. We recorded MPG, aortic valve area (AVA), cardiac output, and ejection fraction (EF) by both methods. Aortic root diameter, left ventricular end-diastolic dimension (LVIDd) and posterior wall thickness (PWT) were measured by echocardiography and gender, heart rate, and heart rhythm were also recorded. An MPG discrepancy was defined as an intrapatient difference > 10 mmHg. Mean pressure gradients by cath and Doppler were 36 +/- 22 mmHg and 37 +/- 20 mmHg, respectively (P = 0.73). Linear regression showed good correlation (r = 0.82) between the techniques. An MPG discrepancy was found in 36 (36%) of 100 evaluations; in 19 (53%) of 36 evaluations MPG by Doppler was higher than cath, and in 17 (47%) of 36, it was lower. In 33 evaluations, EF differed by >10% between techniques. Linear regression analyses revealed that EF difference between studies was a significant predictor of MPG discrepancy (P = 0.004). Women had significantly higher MPG than men by both cath and Doppler (43 +/- 25 mmHg versus 29 +/- 15 mmHg [P = 0.001]; 42 +/- 23 mmHg versus 32 +/- 15 mmHg [P = 0.014], respectively). Women exhibited discrepant results in 23 (47%) of 49 evaluations versus 13 (25%) of 51 evaluations in men (P = 0.037). After adjustment for women's higher MPG, there was no statistically significant difference in MPG discrepancy between genders (P = 0.22). No significant interactions between MPG and aortic root diameter, relative wall thickness (RWT), heart rate, heart rhythm, cardiac output, and time interval between studies were found. In clinical practice, significant discrepancies in MPG were common when cath and Doppler are performed nonsimultaneously. No systematic bias was observed and Doppler results were as likely yield lower as higher MPGs than cath. EF difference was a significant predictor of discrepant MPG. Aortic root diameter, relative wall thickness, heart rate, heart rhythm, cardiac output, presence or severity of coronary artery disease, and time interval between studies were not predictors of discrepant results.
Similar articles
-
Correction of Doppler Gradients for Pressure Recovery Improves Agreement with Subsequent Catheterization Gradients in Congenital Aortic Stenosis.J Am Soc Echocardiogr. 2015 Dec;28(12):1410-7. doi: 10.1016/j.echo.2015.08.016. Epub 2015 Oct 9. J Am Soc Echocardiogr. 2015. PMID: 26454341
-
Independent contribution of left ventricular ejection time to the mean gradient in aortic stenosis.J Heart Valve Dis. 2002 Sep;11(5):615-23. J Heart Valve Dis. 2002. PMID: 12358396
-
Quantification of low-gradient severe aortic stenosis using a hybrid approach combining Doppler echocardiography and thermodilution.J Heart Valve Dis. 2014 May;23(3):271-8. J Heart Valve Dis. 2014. PMID: 25296448
-
Aortic valve stenosis: to the gradient and beyond--the mismatch between area and gradient severity.J Interv Cardiol. 2013 Apr;26(2):183-94. doi: 10.1111/joic.12004. Epub 2012 Dec 30. J Interv Cardiol. 2013. PMID: 23278313 Review.
-
[Standard transthoracic echocardiography examination in patients with degenerative stenosis of the aortic valve].Ultraschall Med. 2012 Dec;33(6):520-38; quiz 539-42. doi: 10.1055/s-0032-1325584. Epub 2012 Dec 7. Ultraschall Med. 2012. PMID: 23225533 Review. German. No abstract available.
Cited by
-
Evaluation of the OpSens OptoWire III and Novel TAVR Algorithm to Measure Pressure Gradient During TAVR.J Soc Cardiovasc Angiogr Interv. 2022 May 17;1(4):100309. doi: 10.1016/j.jscai.2022.100309. eCollection 2022 Jul-Aug. J Soc Cardiovasc Angiogr Interv. 2022. PMID: 39131936 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials