Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005;20(1):45-51.
doi: 10.1007/s10103-005-0336-z. Epub 2005 May 21.

Quantitative optical coherence tomography of arterial wall components

Affiliations
Comparative Study

Quantitative optical coherence tomography of arterial wall components

F J van der Meer et al. Lasers Med Sci. 2005.

Abstract

Optical coherence tomography (OCT) can be used to visualize the arterial wall and atherosclerotic plaques with high resolution. In this study, we verified the application of OCT to the quantitative analysis of plaque structural dimensions and optical attenuation coefficients of the components. We assessed the effect of balloon dilation on the OCT signal from the medial layer of porcine carotid artery ex vivo. Imaging of human autopsy samples was performed from the luminal side with a high (3.5 microm axial and 7 microm lateral) resolution OCT system (approximately 800 nm) or a regular (15-20 microm axial and 20 microm lateral resolution) OCT system (approximately 1,300 nm). For each sample, dimensions were measured by histomorphometry and OCT, and the optical attenuation was measured. In a tissue culture set-up, porcine carotid arteries were dilated and the attenuation coefficients of the dilated segments were compared to a control segment for 4 h. Quantitative analysis showed a strong and significant correlation between OCT and histology cap thickness measurements for both OCT systems. For both systems, the measured attenuation coefficients for diffuse intimal thickening and lipid-rich regions differed significantly from that of calcified tissue. Balloon dilation induced a time-dependent increase in the attenuation coefficient, which may be attributed to the induction of apoptosis. In conclusion both the high and regular resolution OCT systems can image the atherosclerotic plaques precisely. Quantitative analysis of the OCT signals allowed in situ determination of the intrinsic optical attenuation coefficient for atherosclerotic tissue components within regions of interest, which can help to discriminate between plaque and arterial wall components.

PubMed Disclaimer

References

    1. Circulation. 1997 Feb 18;95(4):981-7 - PubMed
    1. Opt Express. 2004 Jan 26;12(2):249-59 - PubMed
    1. Opt Lett. 1997 Jun 15;22(12):934-6 - PubMed
    1. J Am Coll Cardiol. 2002 Feb 20;39(4):604-9 - PubMed
    1. Circulation. 2003 Jan 7;107(1):113-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources