Detection of oligoclonal IgG bands in cerebrospinal fluid by immunofixation after isoelectric focusing on polyacrylamide gels with the PhastSystem
- PMID: 1592046
- DOI: 10.1002/elps.1150130132
Detection of oligoclonal IgG bands in cerebrospinal fluid by immunofixation after isoelectric focusing on polyacrylamide gels with the PhastSystem
Abstract
This paper describes the detection of oligoclonal bands of IgG immunoglobulins in cerebrospinal fluids (CSF) using isoelectric focusing (IEF) and immunofixation with the PhastSystem equipment. The proteins were separated by IEF on polyacrylamide gels, pH 3-9. The IgG immunoglobulins were then fixed by overlaying the gel with antihuman IgG antiserum. Fixed immunoglobulins were detected with silver staining in the PhastSystem Development Unit. One microliter of serum or CSF containing 15 mg/L of IgG was found to be optimal. The procedure had good reproducibility both with regard to IEF and silver staining of the fixed immunoglobulins. The manpower need was reduced, and the procedure has been found to be useful in the clinical laboratory.
Similar articles
-
Oligoclonal IgG in cerebrospinal fluid detected by isoelectric focusing using PhastSystem.Scand J Clin Lab Invest. 1993 Aug;53(5):487-92. doi: 10.1080/00365519309092544. Scand J Clin Lab Invest. 1993. PMID: 8210971
-
Silver staining of cerebrospinal fluid IgG in isoelectric focusing gels.J Neurosci Methods. 1983 Aug;8(4):375-80. doi: 10.1016/0165-0270(83)90094-8. J Neurosci Methods. 1983. PMID: 6194384
-
Detection of oligoclonal IgG bands in unconcentrated CSF by isoelectric focusing in agarose gel and silver staining.J Neurosci Methods. 1986 Jun;16(4):277-82. doi: 10.1016/0165-0270(86)90052-x. J Neurosci Methods. 1986. PMID: 2426528
-
Distinct heterogeneity of IgG immune response in cerebrospinal fluid (CSF) detected by isoelectric focusing (IEF) with extended immunofixation.Brain Res Bull. 2003 Aug 15;61(3):309-20. doi: 10.1016/s0361-9230(03)00094-7. Brain Res Bull. 2003. PMID: 12909301
-
Cerebrospinal fluid in the diagnosis of multiple sclerosis: a consensus report.J Neurol Neurosurg Psychiatry. 1994 Aug;57(8):897-902. doi: 10.1136/jnnp.57.8.897. J Neurol Neurosurg Psychiatry. 1994. PMID: 8057110 Free PMC article. Review.
Cited by
-
Detection of cerebrospinal fluid leakage by isoelectric focusing on polyacrylamide gels with silver staining using the PhastSystem.Acta Neurochir (Wien). 1995;136(3-4):135-9. doi: 10.1007/BF01410615. Acta Neurochir (Wien). 1995. PMID: 8748843
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources