Optical coherence tomography as a tool for percutaneous coronary interventions
Abstract
This study was performed to demonstrate the ability of intravascular optical coherence tomography (OCT) to identify characteristic vascular responses to percutaneous coronary interventions (PCI). OCT provides cross-sectional images of tissue in situ at approximately 10 microm, rendering detailed structural information. Intravascular ultrasound and OCT images were obtained from 10 patients before and after PCI. Images were evaluated to identify balloon-induced dissections/disruptions, thrombus, cutting balloon-induced vascular changes, tissue protrusion, stent apposition and symmetry, and intimal hyperplasia. The disrupted intima, intraluminal thrombus, depth of balloon-induced dissections, cutting balloon cuts, tissue prolapse, underdeployed struts, and intimal hyperplasia were all noticed with OCT. This is the first report of the use of OCT to identify in vivo human intracoronary pathology after PCI.
Comment in
-
The more information, the better results?Catheter Cardiovasc Interv. 2005 Aug;65(4):497-8. doi: 10.1002/ccd.20420. Catheter Cardiovasc Interv. 2005. PMID: 15920720 No abstract available.
Similar articles
-
Recent advances in intracoronary imaging techniques: focus on optical coherence tomography.Expert Rev Med Devices. 2008 Nov;5(6):691-7. doi: 10.1586/17434440.5.6.691. Expert Rev Med Devices. 2008. PMID: 19025345 Review.
-
The more information, the better results?Catheter Cardiovasc Interv. 2005 Aug;65(4):497-8. doi: 10.1002/ccd.20420. Catheter Cardiovasc Interv. 2005. PMID: 15920720 No abstract available.
-
Optical coherence tomography (OCT) in secondary revascularisation: stent and graft assessment.EuroIntervention. 2009 May;5 Suppl D:D93-D100. EuroIntervention. 2009. PMID: 19736079 Review.
-
Incidence, predictors, morphological characteristics, and clinical outcomes of stent edge dissections detected by optical coherence tomography.JACC Cardiovasc Interv. 2013 Aug;6(8):800-13. doi: 10.1016/j.jcin.2013.03.019. Epub 2013 Jul 17. JACC Cardiovasc Interv. 2013. PMID: 23871510
-
Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: evaluation by optical coherence tomography.Chin Med J (Engl). 2008 Mar 20;121(6):503-7. Chin Med J (Engl). 2008. PMID: 18364133
Cited by
-
Erosion/malapposition of a sirolimus eluting stent - optical coherence tomography image - a case report.Indian Heart J. 2012 Nov-Dec;64(6):610-3. doi: 10.1016/j.ihj.2012.11.008. Epub 2012 Nov 27. Indian Heart J. 2012. PMID: 23253419 Free PMC article.
-
Thrombus causes fluctuations in arterial drug delivery from intravascular stents.J Control Release. 2008 Nov 12;131(3):173-80. doi: 10.1016/j.jconrel.2008.07.027. Epub 2008 Jul 25. J Control Release. 2008. PMID: 18713645 Free PMC article.
-
The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography.Yonsei Med J. 2010 May;51(3):332-8. doi: 10.3349/ymj.2010.51.3.332. Yonsei Med J. 2010. PMID: 20376884 Free PMC article.
-
Optical coherence tomography guided PCI - initial experience at Apollo Health City, Jubilee Hills, Hyderabad.Indian Heart J. 2014 Jan-Feb;66(1):31-7. doi: 10.1016/j.ihj.2013.12.048. Epub 2014 Jan 17. Indian Heart J. 2014. PMID: 24581093 Free PMC article.
-
Use of an oxygen-carrying blood substitute to improve intravascular optical coherence tomography imaging.J Biomed Opt. 2009 May-Jun;14(3):034028. doi: 10.1117/1.3153895. J Biomed Opt. 2009. PMID: 19566321 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous