Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2005 Jun 7;111(22):2875-80.
doi: 10.1161/CIRCULATIONAHA.104.491530. Epub 2005 May 31.

Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: a randomized comparison between 2 current ablation strategies

Affiliations
Randomized Controlled Trial

Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: a randomized comparison between 2 current ablation strategies

Martin R Karch et al. Circulation. .

Abstract

Background: Data on the comparative value of the circumferential pulmonary vein and the segmental pulmonary vein ablation for interventional treatment of atrial fibrillation are limited. We hypothesized that the circumferential pulmonary vein ablation approach was superior to the segmental pulmonary vein ablation approach.

Methods and results: One hundred patients with highly symptomatic atrial fibrillation were randomly assigned to undergo either circumferential (n=50) or segmental pulmonary vein ablation (n=50). Freedom from atrial tachyarrhythmias in a 7-day Holter monitoring at 6 months was the primary end point. Secondary end points were freedom of arrhythmia-related symptoms and a composite of pericardial tamponade, thromboembolic complications, and pulmonary vein stenosis (safety end point). On the basis of the results of the 7-day Holter monitoring at 6 months, 21 patients (42%) after circumferential pulmonary vein ablation and 33 patients (66%) after segmental pulmonary vein ablation (P=0.02) were free of atrial tachyarrhythmia episodes. During the 6-month follow-up period, 27 patients (54%) after circumferential pulmonary vein ablation and 41 patients (82%) after segmental pulmonary vein ablation remained free of arrhythmia-related symptoms (P<0.01). No significant difference was found in the safety end point (6 versus 7 events; P=0.77) in the circumferential versus segmental pulmonary vein ablation group, respectively.

Conclusions: This study demonstrates no superiority of the circumferential pulmonary vein ablation over segmental pulmonary vein ablation for treatment of atrial fibrillation in terms of efficacy and safety.

PubMed Disclaimer

Comment in

Publication types

MeSH terms