Vertebroplasty and kyphoplasty affect vertebral motion segment stiffness and stress distributions: a microstructural finite-element study
- PMID: 15928549
- DOI: 10.1097/01.brs.0000163882.27413.01
Vertebroplasty and kyphoplasty affect vertebral motion segment stiffness and stress distributions: a microstructural finite-element study
Abstract
Study design: The mechanical behavior of a thoracic motion segment following cement augmentation was studied using the finite-element method.
Objective: To examine effects of cement augmentation on motion segment stiffness and load transfer.
Summary of background data: Vertebroplasty and kyphoplasty procedures are meant to stiffen and strengthen the vertebral body, but the optimal cement volume and placement to achieve these goals without altering load transfer to adjacent segments are unknown.
Methods: A microstructural finite-element model of a vertebral motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was modeled using an elasto-plastic modulus reduction scheme. Three motion segment damage models were created: I = 18% apparent modulus reduction (least damage), II = 45%, and III = 85% (most damage); and several one- and two-segment polymethylmethacrylate cement repair strategies (partial fill kyphoplasty, replacement of bone and marrow; and both partial fill and complete fill vertebroplasty, replacement of marrow only) were studied. Average disc and bone stresses and motion segment apparent compressive stiffness were compared with baseline (undamaged and untreated) simulation results.
Results: In terms of maximizing stiffness and minimizing stress alterations in the adjacent vertebral body and increasing motion segment apparent stiffness, we found that, other than complete fill, the most effective single-segment cement repair strategy was vertebroplasty on the periphery of the superior segment overlying the disc anulus (<0.1% overall vertebral body bone stress alteration and 83% stiffness increase, respectively, damage Model III). Two-segment vertebroplasty (all repair models) restored motion segment stiffness to baseline levels in all damage models, while single-segment vertebroplasty (all repair models) restored stiffness to baseline levels only in damage Model I. Single- and two-segment kyphoplasty was effective in restoring stiffness to baseline levels for Model I only. Compared with the baseline model, cement augmentation decreased average treated segment bone stresses (up to 66%, complete fill vertebroplasty elasto-plastic modulus reduction Model III), increased average intervertebral disc nucleus stresses (up to 59%, kyphoplasty elasto-plastic modulus reduction Model III), and increased average adjacent segment, endplate region stresses (up to 2.8%, kyphoplasty elasto-plastic modulus reduction Model II). Adjacent (untreated) segment peak bone stresses were increased (up to 45%, kyphoplasty, Model III) in endplate regions underlying the intervertebral disc nucleus.
Conclusions: The damage-repair simulations indicated that cement augmentation improves motion segment stiffness but substantially alters bone stress distributions in treated and adjacent segments.
Similar articles
-
Early stage disc degeneration does not have an appreciable affect on stiffness and load transfer following vertebroplasty and kyphoplasty.Eur Spine J. 2009 Jan;18(1):59-68. doi: 10.1007/s00586-008-0828-1. Epub 2008 Nov 26. Eur Spine J. 2009. PMID: 19034533 Free PMC article.
-
Damage-based finite-element vertebroplasty simulations.Eur Spine J. 2004 Nov;13(7):617-25. doi: 10.1007/s00586-003-0651-7. Epub 2004 Jan 17. Eur Spine J. 2004. PMID: 14730441 Free PMC article.
-
Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies.Spine (Phila Pa 1976). 2009 Dec 15;34(26):2865-73. doi: 10.1097/BRS.0b013e3181b4ea1e. Spine (Phila Pa 1976). 2009. PMID: 20010394
-
Long-term effects of vertebroplasty: adjacent vertebral fractures.J Long Term Eff Med Implants. 2006;16(4):265-80. doi: 10.1615/jlongtermeffmedimplants.v16.i4.10. J Long Term Eff Med Implants. 2006. PMID: 17073569 Review.
-
[Biomechanical aspects of vertebral augmentation].Unfallchirurg. 2015 Oct;118(10):822-30. doi: 10.1007/s00113-015-0066-z. Unfallchirurg. 2015. PMID: 26358323 Review. German.
Cited by
-
Results, experience and technical points learnt with use of the SKy Bone Expander kyphoplasty system for osteoporotic vertebral compression fractures: a prospective study of 40 patients with a minimum of 12 months of follow-up.Eur Spine J. 2007 Nov;16(11):1944-50. doi: 10.1007/s00586-007-0438-3. Epub 2007 Jul 21. Eur Spine J. 2007. PMID: 17659364 Free PMC article.
-
Computational modelling of bone augmentation in the spine.J Orthop Translat. 2015 Oct 1;3(4):185-196. doi: 10.1016/j.jot.2015.09.003. eCollection 2015 Oct. J Orthop Translat. 2015. PMID: 30035057 Free PMC article. Review.
-
Volume matters: a review of procedural details of two randomised controlled vertebroplasty trials of 2009.Eur Spine J. 2010 Nov;19(11):1837-40. doi: 10.1007/s00586-010-1525-4. Epub 2010 Aug 5. Eur Spine J. 2010. PMID: 20686793 Free PMC article. Review.
-
[Vertebroplasty and kyphoplasty in patients with osteoporotic fractures: secured knowledge and open questions].Radiologe. 2006 Oct;46(10):881-92. doi: 10.1007/s00117-006-1391-6. Radiologe. 2006. PMID: 16896638 Review. German.
-
Investigating sacroplasty: technical considerations and finite element analysis of polymethylmethacrylate infusion into cadaveric sacrum.AJNR Am J Neuroradiol. 2007 Jun-Jul;28(6):1036-41. doi: 10.3174/ajnr.A0500. AJNR Am J Neuroradiol. 2007. PMID: 17569952 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials