Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Nov;18(11):1625-30.
doi: 10.1007/s00464-004-8811-3. Epub 2004 Oct 11.

Intraoperative fluid management in laparoscopic live-donor nephrectomy: challenging the dogma

Affiliations
Comparative Study

Intraoperative fluid management in laparoscopic live-donor nephrectomy: challenging the dogma

S Bergman et al. Surg Endosc. 2004 Nov.

Abstract

Background: Patients undergoing laparoscopic live donor nephrectomy (LLDN) commonly receive large amounts of fluid intraoperatively to counter the negative effects of pneumoperitoneum on renal function. Our aim is to demonstrate that a low-volume fluid management strategy does not adversely affect donor or recipient outcomes.

Methods: Fifty-two patients underwent LLDN between December 2000 and January 2004. Data were collected in prospective databases, and augmented with retrospective medical record review. Donors were divided into two groups: the fluid-load group (n = 24) received > 10 ml/kg/h of intravenous crystalloids intraoperatively, while the fluid-restriction group (n = 28) received < 10 m/kg/h.

Results: Donors in the fluid-restriction group had a lower intraoperative urine output. There were no differences in postoperative creatinine levels (117.5 micromol/L vs 121.5 micromol/L, p = 0.8) or complications (4.2% vs 7.1%, p = 0.9). In the recipients, there were no differences in postoperative creatinine levels up to 12 months, incidence of delayed graft function (18% vs 10%, p = 0.7) or acute rejection (9% vs 5%, p = 1.0) between groups.

Conclusion: Lower volume fluid management strategies in LLDN do not appear to worsen recipient outcomes nor are they detrimental to the donors.