Results from the NIST 2004 DNA Quantitation Study
- PMID: 15932088
Results from the NIST 2004 DNA Quantitation Study
Abstract
For optimal DNA short tandem repeat (STR) typing results, the DNA concentration ([DNA]) of the sample must be accurately determined prior to the polymerase chain reaction (PCR) amplification step in the typing process. In early 2004, the National Institute of Standards and Technology (NIST) conducted an interlaboratory study to help assess the accuracy of DNA quantitation in forensic DNA laboratories. This study was designed with four primary purposes: (1) to examine concentration effects and to probe performance at the lower DNA concentration levels that are frequently seen in forensic casework; (2) to examine consistency with various methodologies across multiple laboratories; (3) to examine single versus multiple source samples; and (4) to study DNA stability over time and through shipping in two types of storage tubes. Eight DNA samples of [DNA] from 0.05 ng/microL to 1.5 ng/microL were distributed. A total of 287 independent data sets were returned from 80 participants. Results were reported for 19 different DNA quantitation methodologies. Approximately 65% of the data were obtained using traditional slot blot hybridization methods; 21% were obtained using newly available quantitative real-time PCR (Q-PCR) techniques. Information from this interlaboratory study is guiding development of a future NIST Standard Reference Material for Human DNA Quantitation, SRM 2372.
Similar articles
-
NIST mixed stain studies #1 and #2: interlaboratory comparison of DNA quantification practice and short tandem repeat multiplex performance with multiple-source samples.J Forensic Sci. 2001 Sep;46(5):1199-210. J Forensic Sci. 2001. PMID: 11569565
-
NIST mixed stain study 3: signal intensity balance in commercial short tandem repeat multiplexes.Anal Chem. 2004 Dec 1;76(23):6928-34. doi: 10.1021/ac049178k. Anal Chem. 2004. PMID: 15571343
-
Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.Forensic Sci Int. 2006 Dec 20;164(2-3):240-8. doi: 10.1016/j.forsciint.2006.02.027. Epub 2006 Mar 20. Forensic Sci Int. 2006. PMID: 16542806
-
A review of the DNA standard reference materials developed by the National Institute of Standards and Technology.Fresenius J Anal Chem. 2001 Jun;370(2-3):213-9. doi: 10.1007/s002160100792. Fresenius J Anal Chem. 2001. PMID: 11451239 Review.
-
NIST physical standards for DNA-based medical testing.J Clin Lab Anal. 2002;16(1):5-10. doi: 10.1002/jcla.2062. J Clin Lab Anal. 2002. PMID: 11835524 Free PMC article. Review.
Cited by
-
Fluorescent duplex allele-specific PCR and amplicon melting for rapid homogeneous mtDNA haplogroup H screening and sensitive mixture detection.PLoS One. 2009 Dec 18;4(12):e8374. doi: 10.1371/journal.pone.0008374. PLoS One. 2009. PMID: 20020064 Free PMC article.
-
A graphical simulation model of the entire DNA process associated with the analysis of short tandem repeat loci.Nucleic Acids Res. 2005 Jan 28;33(2):632-43. doi: 10.1093/nar/gki205. Print 2005. Nucleic Acids Res. 2005. PMID: 15681615 Free PMC article.
-
Evaluation of microbial qPCR workflows using engineered Saccharomyces cerevisiae.Biomol Detect Quantif. 2016 Feb 19;7:27-33. doi: 10.1016/j.bdq.2016.01.001. eCollection 2016 Mar. Biomol Detect Quantif. 2016. PMID: 27077050 Free PMC article.
-
Characterization of mtDNA SNP typing and mixture ratio assessment with simultaneous real-time PCR quantification of both allelic states.Int J Legal Med. 2006 Jan;120(1):18-23. doi: 10.1007/s00414-005-0024-3. Epub 2005 Aug 9. Int J Legal Med. 2006. PMID: 16088411
-
Comparison of swab types for collection and analysis of microorganisms.Microbiologyopen. 2021 Nov;10(6):e1244. doi: 10.1002/mbo3.1244. Microbiologyopen. 2021. PMID: 34964289 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources