Nodule detection in digital chest radiography: effect of system noise
- PMID: 15933088
- DOI: 10.1093/rpd/nch525
Nodule detection in digital chest radiography: effect of system noise
Abstract
Apart from the image content that is the reproduction of anatomy and possible lesions, an X-ray image also contains system noise due to the limited number of photons and other internal noise sources in the system (image plate artefacts, electronic noise, etc.). The aim of this study was to determine the extent to which the system noise influences the detection of subtle lung nodules in five different regions of the chest. This was done by conducting a receiver operating characteristic (ROC) study with five observers on two different sets of images; clinical chest X-ray images and images of a LucAl phantom at similar dose levels found in the different regions of the chest. In both image types, mathematically simulated nodules (with a full-width-at-fifth-maximum of 10 mm) were added to the images at varying contrast levels. As a measure of the influence of system noise on the detection of subtle lung nodules, the ratio between the contrast needed to obtain an area under the ROC curve of 0.80 in the system noise images to that needed in the clinical images was used. The contrast ratio between system noise images and clinical images ranged from approximately 0.02 (in the hilar region) to 0.18 (in the lower mediastinal region). The maximum difference in contrast needed for the corresponding system noise images, collected at the lowest and the highest dose represented in the anatomical image, was a factor of 2. These results indicate that probably no region in a chest X-ray image is limited by the number of quanta to the detector for the detection of 10 mm lung nodules when a radiation dose corresponding to a system with speed class 200 (leading to a detector dose of approximately 9 muGy behind the parenchyma) is used.
Similar articles
-
Nodule detection in digital chest radiography: part of image background acting as pure noise.Radiat Prot Dosimetry. 2005;114(1-3):102-8. doi: 10.1093/rpd/nch523. Radiat Prot Dosimetry. 2005. PMID: 15933089 Clinical Trial.
-
Nodule detection in digital chest radiography: effect of anatomical noise.Radiat Prot Dosimetry. 2005;114(1-3):109-13. doi: 10.1093/rpd/nch526. Radiat Prot Dosimetry. 2005. PMID: 15933090 Clinical Trial.
-
Nodule detection in digital chest radiography: effect of nodule location.Radiat Prot Dosimetry. 2005;114(1-3):92-6. doi: 10.1093/rpd/nch524. Radiat Prot Dosimetry. 2005. PMID: 15933087 Clinical Trial.
-
Digital tomosynthesis of the chest.J Thorac Imaging. 2008 May;23(2):86-92. doi: 10.1097/RTI.0b013e318173e162. J Thorac Imaging. 2008. PMID: 18520565 Review.
-
Dose and perceived image quality in chest radiography.Eur J Radiol. 2009 Nov;72(2):209-17. doi: 10.1016/j.ejrad.2009.05.039. Epub 2009 Jul 3. Eur J Radiol. 2009. PMID: 19577393 Review.
Cited by
-
Use of a digitally reconstructed radiograph-based computer simulation for the optimisation of chest radiographic techniques for computed radiography imaging systems.Br J Radiol. 2012 Sep;85(1017):e630-9. doi: 10.1259/bjr/47377285. Epub 2012 Jan 17. Br J Radiol. 2012. PMID: 22253349 Free PMC article.
-
Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.Br J Radiol. 2013 Jul;86(1027):20130077. doi: 10.1259/bjr.20130077. Epub 2013 Apr 8. Br J Radiol. 2013. PMID: 23568362 Free PMC article.
-
Investigating the use of an antiscatter grid in chest radiography for average adults with a computed radiography imaging system.Br J Radiol. 2015 Mar;88(1047):20140613. doi: 10.1259/bjr.20140613. Epub 2015 Jan 9. Br J Radiol. 2015. PMID: 25571914 Free PMC article.
-
An investigation into the validity of utilising the CDRAD 2.0 phantom for optimisation studies in digital radiography.Br J Radiol. 2018 Sep;91(1089):20180317. doi: 10.1259/bjr.20180317. Epub 2018 Jul 5. Br J Radiol. 2018. PMID: 29906239 Free PMC article.
-
Evaluation of an artificial intelligence noise reduction tool for conventional X-ray imaging - a visual grading study of pediatric chest examinations at different radiation dose levels using anthropomorphic phantoms.Pediatr Radiol. 2025 Jun;55(7):1475-1486. doi: 10.1007/s00247-025-06251-0. Epub 2025 May 13. Pediatr Radiol. 2025. PMID: 40358694 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials