Nodule detection in digital chest radiography: effect of anatomical noise
- PMID: 15933090
- DOI: 10.1093/rpd/nch526
Nodule detection in digital chest radiography: effect of anatomical noise
Abstract
The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within the RADIUS group. The aim of the present study was to investigate whether the removal of the anatomical noise results in images where lung nodules with lower contrast can be detected. A receiver operating characteristic (ROC) study was therefore conducted using two types of images: clinical chest images and chest images in which the anatomical noise had been removed. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. The contrast needed to obtain an area under the ROC curve of 0.80, C0.8, was used as a measure of detectability (a low value of C0.8 represents a high detectability). Five regions of the chest X ray were investigated and it was found that in all regions the removal of anatomical noise led to images with lower C0.8 than the original images. On average, C0.8 was 20% higher in the original images, ranging from 7% (the lateral pulmonary regions) to 41% (the upper mediastinal regions).
Similar articles
-
Nodule detection in digital chest radiography: effect of system noise.Radiat Prot Dosimetry. 2005;114(1-3):97-101. doi: 10.1093/rpd/nch525. Radiat Prot Dosimetry. 2005. PMID: 15933088 Clinical Trial.
-
Nodule detection in digital chest radiography: effect of nodule location.Radiat Prot Dosimetry. 2005;114(1-3):92-6. doi: 10.1093/rpd/nch524. Radiat Prot Dosimetry. 2005. PMID: 15933087 Clinical Trial.
-
Nodule detection in digital chest radiography: part of image background acting as pure noise.Radiat Prot Dosimetry. 2005;114(1-3):102-8. doi: 10.1093/rpd/nch523. Radiat Prot Dosimetry. 2005. PMID: 15933089 Clinical Trial.
-
Digital tomosynthesis of the chest.J Thorac Imaging. 2008 May;23(2):86-92. doi: 10.1097/RTI.0b013e318173e162. J Thorac Imaging. 2008. PMID: 18520565 Review.
-
Practical applications of digital tomosynthesis of the chest.Clin Radiol. 2014 Apr;69(4):424-30. doi: 10.1016/j.crad.2013.10.019. Epub 2013 Dec 13. Clin Radiol. 2014. PMID: 24333001 Review.
Cited by
-
Dose estimation of ultra-low-dose chest CT to different sized adult patients.Eur Radiol. 2019 Aug;29(8):4315-4323. doi: 10.1007/s00330-018-5849-5. Epub 2018 Dec 17. Eur Radiol. 2019. PMID: 30560356
-
Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis.Eur Radiol. 2014 Jul;24(7):1529-36. doi: 10.1007/s00330-014-3182-1. Epub 2014 May 4. Eur Radiol. 2014. PMID: 24792590
-
Investigating the use of an antiscatter grid in chest radiography for average adults with a computed radiography imaging system.Br J Radiol. 2015 Mar;88(1047):20140613. doi: 10.1259/bjr.20140613. Epub 2015 Jan 9. Br J Radiol. 2015. PMID: 25571914 Free PMC article.
-
Use of a digitally reconstructed radiograph-based computer simulation for the optimisation of chest radiographic techniques for computed radiography imaging systems.Br J Radiol. 2012 Sep;85(1017):e630-9. doi: 10.1259/bjr/47377285. Epub 2012 Jan 17. Br J Radiol. 2012. PMID: 22253349 Free PMC article.
-
Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography.Acta Radiol Open. 2016 Dec 1;5(12):2058460116684884. doi: 10.1177/2058460116684884. eCollection 2016 Dec. Acta Radiol Open. 2016. PMID: 28405477 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical