A semi-active milling procedure in view of preparing implantation beds in robot-assisted orthopaedic surgery
- PMID: 15934392
- DOI: 10.1243/095441105X9381
A semi-active milling procedure in view of preparing implantation beds in robot-assisted orthopaedic surgery
Abstract
Bone cutting in total joint reconstructions requires a high accuracy to obtain a well-functioning and long-lasting prosthesis. Hence robot assistance can be useful to increase the precision of the surgical actions. A drawback of current robot systems is that they autonomously machine the bone, in that way ignoring the surgeon's experience and introducing a safety risk. This paper presents a semi-active milling procedure to overcome that drawback. In this procedure the surgeon controls robot motion by exerting forces on a force-controlled lever that is attached to the robot end effector. Meanwhile the robot constrains tool motion to the planned motion and generates a tool feed determined by the feed force that the surgeon executes. As a case study the presented milling procedure has been implemented on a laboratory set-up for robot-assisted preparation of the acetabulum in total hip arthroplasty. Two machining methods have been considered. In the first method the surgeon determines both milling trajectory and feed by the forces that he/she executes on the force-controlled lever. In the second method the cavity is machined contour by contour, and the surgeon only provides the feed. Machining experiments have shown that the first method results in large surface irregularities and is not useful. The second method, however, results in accurate cavity preparation and has therefore potential to be implemented in future robot systems.
Similar articles
-
The dimensional accuracy for preparation of the femoral cavity in HIP arthroplasty. A comparison between manual- and robot-assisted implantation of hip endoprosthesis stems in cadaver femurs.Arch Orthop Trauma Surg. 2006 Jan;126(1):36-44. doi: 10.1007/s00402-005-0080-7. Epub 2005 Dec 8. Arch Orthop Trauma Surg. 2006. PMID: 16341537
-
[Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation].Z Orthop Ihre Grenzgeb. 2004 May-Jun;142(3):303-8. doi: 10.1055/s-2004-822666. Z Orthop Ihre Grenzgeb. 2004. PMID: 15250002 German.
-
Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.Int J Med Robot. 2011 Dec;7(4):469-74. doi: 10.1002/rcs.423. Epub 2011 Oct 7. Int J Med Robot. 2011. PMID: 22113980 Clinical Trial.
-
Precision surgery.Orthopedics. 2009 Sep;32(9):orthosupersite.com/view.asp?rID=42847. doi: 10.3928/01477447-20090728-26. Orthopedics. 2009. PMID: 19751022 Review.
-
Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery.Expert Rev Med Devices. 2009 Sep;6(5):507-14. doi: 10.1586/erd.09.34. Expert Rev Med Devices. 2009. PMID: 19751123 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials