Is there a place for duplex screening of the brachial artery in the maturation of arteriovenous fistulas?
- PMID: 15934972
- DOI: 10.1111/j.1525-139X.2005.18320.x
Is there a place for duplex screening of the brachial artery in the maturation of arteriovenous fistulas?
Abstract
Clinically there are some autogenous arteriovenous fistulas (AVFs) that are obviously mature. The real problem in clinical evaluation is in predicting the ultimate outcome of AVFs that are not clearly mature. Thus it would be advantageous to develop objective quantitative criteria to be applied early after vascular access placement in order to evaluate the suitability of AVFs for dialysis. The goal of this study was to document the blood flow rate modifications that the construction and maturation of a radiocephalic wrist AVF produce in the brachial artery by means of duplex Doppler ultrasonography. All incident uremic patients who needed the construction of a radiocephalic wrist AVF in the last 9 months of 2003 were enrolled in the study: 18 patients underwent such an operation. A linear color Doppler ultrasound scan was performed with a 7.0 MHz imaging/5.0 MHz Doppler probe by sampling the brachial artery 2 cm above the elbow: the internal diameter of the artery was measured and its blood flow rate calculated just before AVF construction and 1, 7, 28 days, and at least 6 months after AVF construction. The internal diameter and blood flow rate of the brachial artery were, respectively, 4.3 +/- 0.7 mm and 56.1 +/- 19.2 ml/min at baseline. A new AVF was constructed in one patient whose brachial artery blood flow rate was 80.0 ml/min at 28 days. When excluding this AVF, the mean brachial artery blood flow rate of the 17 AVFs was 720.4 +/- 132.8 ml/min (median 750 ml/min, range 480-890 ml/min) at 28 days and 997.6 +/- 259.7 ml/min 258.0 +/- 63.0 days after AVF construction. When analyzing the percent increase in brachial artery blood flow rate of the 17 AVFs at the different time points, the most dramatic one occurred at day 1 compared to the baseline (549.0%; mean blood flow rate at day 1, 365.0 +/- 129.3 ml/min). Thus the blood flow rate at day 1 represents more than half (50.7%) of the blood flow rate that will be measured at day 28. Then the increase was less steep, with a 20.1% increase between day 7 and day 1 (mean blood flow rate at day 7, 438.4 +/- 86.0 ml/min), a 64.3% increase between day 28 and day 7, and a 38.5% increase at 258.0 +/- 63.0 days compared to 28 days. The present study was able to document the changes in brachial blood flow rate consequent to a radiocephalic wrist AVF maturation by means of duplex Doppler ultrasonography of the brachial artery. This measure may be helpful in monitoring which AVFs will probably fail. This screening should integrate clinical assessment, thus allowing sound judgment of the level of maturation of an AVF and of its outcome.
Similar articles
-
Predicting arteriovenous fistula maturation with intraoperative blood flow measurements.J Vasc Access. 2008 Oct-Dec;9(4):241-7. J Vasc Access. 2008. PMID: 19085893
-
The natural history of autogenous radio-cephalic wrist arteriovenous fistulas of haemodialysis patients: a prospective observational study.Nephrol Dial Transplant. 2004 May;19(5):1231-6. doi: 10.1093/ndt/gfh073. Epub 2004 Feb 19. Nephrol Dial Transplant. 2004. PMID: 14993512 Clinical Trial.
-
Estimation of brachial artery volume flow by duplex ultrasound imaging predicts dialysis access maturation.J Vasc Surg. 2015 Jun;61(6):1521-7. doi: 10.1016/j.jvs.2015.01.036. Epub 2015 Mar 11. J Vasc Surg. 2015. PMID: 25769390
-
Interpretation of duplex ultrasound dialysis access testing.Semin Vasc Surg. 2013 Jun-Sep;26(2-3):120-6. doi: 10.1053/j.semvascsurg.2013.12.001. Epub 2013 Dec 4. Semin Vasc Surg. 2013. PMID: 24636609 Review.
-
[Doppler sonography of arteriovenous fistulas for haemodialysis].Tidsskr Nor Laegeforen. 2009 Aug 27;129(16):1635-8. doi: 10.4045/tidsskr.09.34272. Tidsskr Nor Laegeforen. 2009. PMID: 19721479 Review. Norwegian.
Cited by
-
Vascular remodeling in autogenous arterio-venous fistulas by MRI and CFD.Ann Biomed Eng. 2013 Apr;41(4):657-68. doi: 10.1007/s10439-012-0703-4. Epub 2012 Nov 27. Ann Biomed Eng. 2013. PMID: 23188560 Free PMC article.
-
Autologous arteriovenous fistula is associated with superior outcomes in elderly hemodialysis patients.BMC Nephrol. 2018 Nov 6;19(1):306. doi: 10.1186/s12882-018-1109-9. BMC Nephrol. 2018. PMID: 30400882 Free PMC article.
-
Basics for performing a high-quality color Doppler sonography of the vascular access.J Vasc Access. 2021 Nov;22(1_suppl):18-31. doi: 10.1177/11297298211018060. Epub 2021 Jul 28. J Vasc Access. 2021. PMID: 34320855 Free PMC article. Review.
-
Discriminative role of brachial artery Doppler parameters in correlation with hemodialysis arteriovenous fistula.Clujul Med. 2017;90(4):407-410. doi: 10.15386/cjmed-728. Epub 2017 Oct 20. Clujul Med. 2017. PMID: 29151789 Free PMC article.
-
The Predictive Significance of Doppler Parameters on the Arteriovenous Fistula Maturation for Hemodialysis-A Single Center Experience.Indian J Nephrol. 2024 Nov-Dec;34(6):630-635. doi: 10.25259/ijn_3_24. Epub 2024 Jun 24. Indian J Nephrol. 2024. PMID: 39649327 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical