Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Aug 1;343(1):106-15.
doi: 10.1016/j.ab.2005.04.026.

Statistical error in isothermal titration calorimetry: variance function estimation from generalized least squares

Affiliations

Statistical error in isothermal titration calorimetry: variance function estimation from generalized least squares

Joel Tellinghuisen. Anal Biochem. .

Abstract

The method of generalized least squares (GLS) is used to assess the variance function for isothermal titration calorimetry (ITC) data collected for the 1:1 complexation of Ba(2+) with 18-crown-6 ether. In the GLS method, the least squares (LS) residuals from the data fit are themselves fitted to a variance function, with iterative adjustment of the weighting function in the data analysis to produce consistency. The data are treated in a pooled fashion, providing 321 fitted residuals from 35 data sets in the final analysis. Heteroscedasticity (nonconstant variance) is clearly indicated. Data error terms proportional to q(i) and q(i)/v are well defined statistically, where q(i) is the heat from the ith injection of titrant and v is the injected volume. The statistical significance of the variance function parameters is confirmed through Monte Carlo calculations that mimic the actual data set. For the data in question, which fall mostly in the range of q(i)=100-2000 microcal, the contributions to the data variance from the terms in q(i)(2) typically exceed the background constant term for q(i)>300 microcal and v<10 microl. Conversely, this means that in reactions with q(i) much less than this, heteroscedasticity is not a significant problem. Accordingly, in such cases the standard unweighted fitting procedures provide reliable results for the key parameters, K and DeltaH(degrees) and their statistical errors. These results also support an important earlier finding: in most ITC work on 1:1 binding processes, the optimal number of injections is 7-10, which is a factor of 3 smaller than the current norm. For high-q reactions, where weighting is needed for optimal LS analysis, tips are given for using the weighting option in the commercial software commonly employed to process ITC data.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources