Rapid mutation detection in complex genes by heteroduplex analysis with capillary array electrophoresis
- PMID: 15937982
- DOI: 10.1002/elps.200410425
Rapid mutation detection in complex genes by heteroduplex analysis with capillary array electrophoresis
Abstract
Mutational analysis of large multiexon genes without prevalent mutations is a laborious undertaking that requires the use of a high-throughput scanning technique. The Human Genome Project has enabled the development of powerful techniques for mutation detection in large multiexon genes. We have transferred heteroduplex analysis (HA) by conformation-sensitive gel electrophoresis of the two major breast cancer (BC) predisposing genes, BRCA1 and BRCA2, to a multicapillary DNA sequencer in order to increase the throughput of this technique. This new method that we have called heteroduplex analysis by capillary array electrophoresis (HA-CAE) is based on the use of multiplex-polymerase chain reaction (PCR), different fluorescent labels and HA in a 16-capillary DNA sequencer. To date, a total of 114 different DNA sequence variants (19 insertions/deletions and 95 single-nucleotide substitutions - SNS) of BRCA1 and BRCA2 from 431 unrelated BC families have been successfully detected by HA-CAE. In addition, we have optimized the multiplex-PCR conditions for the colorectal cancer genes MLH1 and MSH2 in order to analyze them by HA-CAE. Both genes have been amplified in 13 multiplex groups, which contain the 35 exons, and their corresponding flanking intronic sequences. MLH1 and MSH2 have been analyzed in nine hereditary nonpolyposis colorectal cancer patients, and we have found six different DNA changes: one complex deletion/insertion mutation in MLH1 exon 19 and another five SNS. Only the complex mutation and one SNS may be classified as cancer-prone mutations. Our experience has revealed that HA-CAE is a simple, fast, reproducible and sensitive method to scan the sequences of complex genes.
Similar articles
-
Heteroduplex analysis by capillary array electrophoresis for rapid mutation detection in large multiexon genes.Nat Protoc. 2007;2(1):237-46. doi: 10.1038/nprot.2006.482. Nat Protoc. 2007. PMID: 17401359
-
Twenty-three novel BRCA1 and BRCA2 sequence alterations in breast and/or ovarian cancer families of Eastern Spain.Breast Cancer Res Treat. 2008 Nov;112(1):69-73. doi: 10.1007/s10549-007-9818-y. Epub 2007 Dec 1. Breast Cancer Res Treat. 2008. PMID: 18060494
-
High-throughput mutation detection method to scan BRCA1 and BRCA2 based on heteroduplex analysis by capillary array electrophoresis.Clin Chem. 2004 Feb;50(2):313-20. doi: 10.1373/clinchem.2003.023614. Epub 2003 Dec 18. Clin Chem. 2004. PMID: 14684619
-
Enhanced mismatch mutation analysis: simultaneous detection of point mutations and large scale rearrangements by capillary electrophoresis, application to BRCA1 and BRCA2.Methods Mol Biol. 2010;653:147-80. doi: 10.1007/978-1-60761-759-4_9. Methods Mol Biol. 2010. PMID: 20721742 Review.
-
Pitfalls and caveats in BRCA sequencing.Ultrastruct Pathol. 2006 May-Jun;30(3):229-35. doi: 10.1080/01913120500521281. Ultrastruct Pathol. 2006. PMID: 16825125 Review.
Cited by
-
High proportion of novel mutations of BRCA1 and BRCA2 in breast/ovarian cancer patients from Castilla-León (central Spain).J Hum Genet. 2006;51(7):611-7. doi: 10.1007/s10038-006-0404-7. Epub 2006 Jun 7. J Hum Genet. 2006. PMID: 16758124
-
Splicing Analysis of 16 PALB2 ClinVar Variants by Minigene Assays: Identification of Six Likely Pathogenic Variants.Cancers (Basel). 2022 Sep 19;14(18):4541. doi: 10.3390/cancers14184541. Cancers (Basel). 2022. PMID: 36139699 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous