Review
. 2005 Jun;94(6):383-91.
doi: 10.1007/s00392-005-0231-4.

Biocompatibility screening in cardiovascular implants

Affiliations
Review

Biocompatibility screening in cardiovascular implants

M Sigler et al. Z Kardiol. 2005 Jun.

Abstract

Background: Interest in information on biocompatibility of implants is increasing. The purpose of this paper is to discuss methods and results of pathological biocompatibility screening of explanted cardiovascular implants.

Methods: Use of standard histology after embedding in paraffin is limited since metallic implants have to be removed during workup with disruption of the specimen. Alternatively, tissue blocks containing an implant can be embedded in methylmethacrylate or hydroxyethylmethacrylate and processed by sectioning with a diamond cutter and grinding, thus leaving the implant in situ and saving the tissue/implant interface for detection of local inflammatory reactions. Another important aspect of evaluation is the progress of thrombus organisation after initial fibrin clotting on the metal surface or in the inner part of occlusion devices. New methacrylate resins and embedding techniques allow for specific immunohistochemical staining of the specimen thus enabling characterisation of tissues surrounding the implant. Information on endothelialisation of the vascular surface of the implant can be obtained by means of immunohistochemistry or by scanning electron microscopy.

Results: Illustrating the use of these technologies, we demonstrate findings in tissue specimens from animal studies with different types of devices (i.e. stents, occlusion devices). We present corresponding findings in human specimens with implants that were removed during corrective surgery for congenital heart defects. Early endothelialisation of the vascular surface was seen after implantation in all types of devices. Cells within occlusion devices could be characterised histologically and immunohistochemically as fibromuscular cells as seen in intimal hyperplasia after stent implantation. Inflammatory implant-host reactions ranged from mild to moderate (medical grade stainless steel, nitinol) to severe (polytetrafluoroethylene [PTFE]).

Conclusions: With an optimal work-up of cardiovascular implants, ingrowth and endothelialisation as well as inflammatory reactions in the surrounding tissue can be assessed. This information allows evaluation of individual tissue reactions to the implant and may serve as valuable basis for optimisation of biocompatibility by implant modification.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Thorac Cardiovasc Surg. 2000 Jul;120(1):134-41 - PubMed
    1. Eur Heart J. 2000 Nov;21(21):1739-49 - PubMed
    1. Rev Cardiovasc Med. 2002 Fall;3(4):176-82 - PubMed
    1. Baillieres Best Pract Res Clin Haematol. 1999 Sep;12(3):329-41 - PubMed
    1. J Biomed Mater Res. 1996 May;31(1):1-9 - PubMed

MeSH terms

Substances

LinkOut - more resources