Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Jun;129(6):1364-70.
doi: 10.1016/j.jtcvs.2004.10.034.

Integrated computed tomography-positron emission tomography in patients with potentially resectable malignant pleural mesothelioma: Staging implications

Affiliations
Free article

Integrated computed tomography-positron emission tomography in patients with potentially resectable malignant pleural mesothelioma: Staging implications

Jeremy J Erasmus et al. J Thorac Cardiovasc Surg. 2005 Jun.
Free article

Abstract

Background: Integrated computed tomography-positron emission tomography imaging with coregistration of anatomic and functional imaging data may improve the accuracy of malignant pleural mesothelioma staging. We evaluate the use of integrated computed tomography-positron emission tomography in patients with malignant pleural mesothelioma who are being considered for extrapleural pneumonectomy.

Methods: Twenty-nine patients with malignant pleural mesothelioma who were judged to be candidates for extrapleural pneumonectomy after clinical and conventional radiologic evaluation underwent whole-body integrated computed tomography-positron emission tomography and pathologic staging. Two reviewers blinded to the results of clinical and pathologic staging retrospectively evaluated computed tomography, positron emission tomography, and coregistered computed tomography-positron emission tomography images. Staging was performed according to the International Mesothelioma Interest Group TNM staging system. Histopathology and/or results of further radiologic evaluation or follow-up served as the reference standard.

Results: Integrated computed tomography-positron emission tomography provided additional information in 11 of 29 patients that precluded extrapleural pneumonectomy. The overall tumor stage was correctly classified in 21 of 29 patients. The tumor stage was correctly determined in 15 of 24 patients, 6 of whom had T4 (nonresectable) disease. The node stage was accurately determined in 6 of 17 patients. Extrathoracic metastases not identified by routine clinical and conventional radiologic evaluation were detected in 7 of 29 patients and were found to be diffuse (n = 2) or solitary (n = 5).

Conclusions: Integrated computed tomography-positron emission tomography increases the accuracy of malignant pleural mesothelioma staging and is important in determining the appropriate therapy in patients being considered for extrapleural pneumonectomy.

PubMed Disclaimer

Similar articles

Cited by