Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Jun;40(11):644-8.

[Evaluation of the diagnostic value of a Spanish adaptation of the Buschke Memory Impairment Screen in the detection of dementia and cognitive impairment]

[Article in Spanish]
Affiliations
  • PMID: 15948064

[Evaluation of the diagnostic value of a Spanish adaptation of the Buschke Memory Impairment Screen in the detection of dementia and cognitive impairment]

[Article in Spanish]
D A Pérez-Martinez et al. Rev Neurol. 2005 Jun.

Abstract

Introduction: Screening tests for dementia are a fundamental tool in specialist consultation and primary care. The instruments currently used are time-consuming and the diagnostic performance they offer is rather poor. The original version of the Buschke Memory Impairment Screen (MIS) is a quick simple test with high discriminatory power.

Aims: Our aim was to validate a Spanish version of the MIS in specialist consultation.

Patients and methods: We conducted a prospective study in 91 subjects aged over 60 who visited the outpatient department for cognitive evaluation. All the patients received a similar diagnostic evaluation and the MIS was administered as a blind test. This Spanish version of the MIS was produced by means of a cross-cultural adaptation.

Results: The area below the ROC curve for dementia on the MIS was 0.92, with a similar result for cognitive deterioration (CD). A cut-off score of 4 or less offered a sensitivity rate of 91.9% (CI 95%: 83.4-96.4%) and a specificity level of 81.0% (CI 95%; 70.3-88.6%) for the detection of CD. Likewise, a cut-off score of 3 or below presented a sensitivity rate of 96.1% (CI 95%: 85.7-99.3%) and a degree of specificity of 72.6% (CI 95%: 63.2-80.3%) for the detection of dementia. Interobserver and test-retest reliability (0.85 and 0.81, respectively) were adequate.

Conclusions: This version of the Buschke MIS offers a high level of discriminatory power both for dementia and for CD, as well as an adequate degree of inter and intraobserver reliability within the context of a specialist consultation. Because it is quick (less than 4 minutes) and simple to administer, MIS represents a reasonable alternative to other screening methods.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources