Stable hybridoma cultivation in a pilot-scale acoustic perfusion system: long-term process performance and effect of recirculation rate
- PMID: 15959892
- DOI: 10.1002/bit.20552
Stable hybridoma cultivation in a pilot-scale acoustic perfusion system: long-term process performance and effect of recirculation rate
Abstract
Perfusion systems have the possibility to be operated continuously for several months. It is important that the performance of the cell retention device does not limit the operation time of a perfusion process used in the production of active pharmaceutical ingredients. Therefore, the aim of this study was to investigate the reliability and long-term stability of an acoustic perfusion process using the 200 L/d BioSep. As the BioSep is an external device, it is possible that dependent on the recirculation rate nutrient gradients occur in the external loop, which could affect the cell metabolism. Therefore, the effect of possible nutrient gradients on cell metabolism, viability and productivity was studied by varying the recirculation rate. In this study, it is shown that a perfusion process using a pilot-scale acoustic cell-retention device (200 L/d) is reliable and simple to operate, resulting in a stable 75-day cultivation of a hybridoma cell line producing a monoclonal antibody. The recirculation rate had a significant effect on the oxygen concentration in the external loop, with oxygen being depleted within the cell-retention device at recirculation rates below 6 m3/m(reactor)3.d (=600 L/d). The oxygen depletion at low circulation rates correlated with a slightly increased lactate production rate. For all other parameters no effect of the recirculation rate was observed, including cell death measured through the release of lactate dehydrogenase and specific productivity. A maximum specific productivity of 12 pg/cell.d was reached.
Copyright 2005 Wiley Periodicals, Inc
Similar articles
-
The production of monoclonal antibody in growth-arrested hybridomas cultivated in suspension and immobilized modes.Biotechnol Prog. 1999 Jul-Aug;15(4):655-66. doi: 10.1021/bp990068m. Biotechnol Prog. 1999. PMID: 10441357
-
Effect of feed and bleed rate on hybridoma cells in an acoustic perfusion bioreactor: part I. Cell density, viability, and cell-cycle distribution.Biotechnol Bioeng. 2004 Dec 5;88(5):547-57. doi: 10.1002/bit.20287. Biotechnol Bioeng. 2004. PMID: 15459904
-
Perfusion culture of hybridoma cells for hyperproduction of IgG(2a) monoclonal antibody in a wave bioreactor-perfusion culture system.Biotechnol Prog. 2007 Jan-Feb;23(1):255-64. doi: 10.1021/bp060299a. Biotechnol Prog. 2007. PMID: 17269696
-
Acoustic cell filter: a proven cell retention technology for perfusion of animal cell cultures.Biotechnol Adv. 2004 Jul;22(6):433-44. doi: 10.1016/j.biotechadv.2004.03.003. Biotechnol Adv. 2004. PMID: 15135491 Review.
-
Getting higher yields of monoclonal antibody in culture.Indian J Physiol Pharmacol. 1998 Apr;42(2):155-71. Indian J Physiol Pharmacol. 1998. PMID: 10225044 Review.
Cited by
-
Living with heterogeneities in bioreactors: understanding the effects of environmental gradients on cells.Mol Biotechnol. 2006 Nov;34(3):355-81. doi: 10.1385/MB:34:3:355. Mol Biotechnol. 2006. PMID: 17284782 Review.
-
Performance of an acoustic settler versus a hollow fiber-based ATF technology for influenza virus production in perfusion.Appl Microbiol Biotechnol. 2020 Jun;104(11):4877-4888. doi: 10.1007/s00253-020-10596-x. Epub 2020 Apr 15. Appl Microbiol Biotechnol. 2020. PMID: 32291490 Free PMC article.
-
Quantification of the dynamics of population heterogeneities in CHO cultures with stably integrated fluorescent markers.Anal Bioanal Chem. 2020 Apr;412(9):2065-2080. doi: 10.1007/s00216-020-02401-5. Epub 2020 Mar 4. Anal Bioanal Chem. 2020. PMID: 32130440 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources