Clinical validation of common carotid artery wall distension assessment based on multigate Doppler processing
- PMID: 15972199
- DOI: 10.1016/j.ultrasmedbio.2005.04.001
Clinical validation of common carotid artery wall distension assessment based on multigate Doppler processing
Abstract
Mechanical properties of human large arteries result from the interaction between blood pressure, wall distensibility and shear stress. Both the arterial diameter changes through the cardiac cycle (distension) and blood flow velocities can be noninvasively investigated through Doppler ultrasound approaches. Recently, an integrated system processing in real-time all the echo signals produced along an M-line has been developed. This system has been so far demonstrated to be suitable for accurate hemodynamic studies through the detection of blood velocity profiles. This paper reports on the extension of its processing capabilities to the real-time measurement of arterial distension. Tissue motion estimation is based on a modified 2-D autocorrelation algorithm. A novel adaptive approach to track wall position over time using the sum of the high-pass filtered displacement waveform and the low-pass filtered wall position is described. By observing the blood velocity profile, a rapid and accurate positioning of the ultrasound probe and an inherent check on perpendicular observation are provided. First clinical results obtained by measuring the distension of common carotid arteries in a group of 41 volunteers are reported and measurements are validated against those provided by a dedicated wall-track reference system. Average measured distension and diameter were 499 +/- 188 microm and 6.90 +/- 0.66 mm and intraobserver intrasession reproducibility tests showed coefficients of variability of 8.5% and 5.9%, respectively. The agreement between the proposed system and the reference system, expressed as bias +/- 2 SD of the differences, was -34 +/- 141 microm for distension and 0.05 +/- 1.07 mm for diameter.
Similar articles
-
Assessment of arterial distension based on continuous wave Doppler ultrasound with an improved Hilbert-Huang processing.IEEE Trans Ultrason Ferroelectr Freq Control. 2010 Jan;57(1):203-13. doi: 10.1109/TUFFC.2010.1399. IEEE Trans Ultrason Ferroelectr Freq Control. 2010. PMID: 20040447
-
Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries.Ultrasound Med Biol. 2006 Nov;32(11):1661-70. doi: 10.1016/j.ultrasmedbio.2006.07.023. Ultrasound Med Biol. 2006. PMID: 17112953
-
A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate.Med Phys. 2010 Aug;37(8):4318-30. doi: 10.1118/1.3462592. Med Phys. 2010. PMID: 20879592
-
Ultrasonic investigation of blood flow.Proc Inst Mech Eng H. 1999;213(3):169-80. doi: 10.1243/0954411991534898. Proc Inst Mech Eng H. 1999. PMID: 10420772 Review.
-
Non-invasive measurement of mechanical properties of arteries in health and disease.Proc Inst Mech Eng H. 1999;213(3):195-202. doi: 10.1243/0954411991534924. Proc Inst Mech Eng H. 1999. PMID: 10490292 Review.
Cited by
-
Progress in atherosclerotic plaque imaging.World J Radiol. 2012 Aug 28;4(8):353-71. doi: 10.4329/wjr.v4.i8.353. World J Radiol. 2012. PMID: 22937215 Free PMC article.
-
Detectable Bias between Vascular Ultrasound Echo-Tracking Systems: Relevance Depends on Application.J Clin Med. 2022 Dec 21;12(1):69. doi: 10.3390/jcm12010069. J Clin Med. 2022. PMID: 36614870 Free PMC article.
-
Automatic Measurement of the Carotid Blood Flow for Wearable Sensors: A Pilot Study.Sensors (Basel). 2021 Aug 31;21(17):5877. doi: 10.3390/s21175877. Sensors (Basel). 2021. PMID: 34502768 Free PMC article.
-
Carotid artery distensibility: a reliability study.J Ultrasound Med. 2007 Sep;26(9):1157-65. doi: 10.7863/jum.2007.26.9.1157. J Ultrasound Med. 2007. PMID: 17715309 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources