Glucose measurements with sensors and ultrasound
- PMID: 15972203
- DOI: 10.1016/j.ultrasmedbio.2005.04.004
Glucose measurements with sensors and ultrasound
Abstract
Accurate monitoring of the blood glucose level in diabetics is essential in preventing complications. Generally, conventional over-the-counter glucose meters require frequent painful finger punctures to obtain samples, which makes a noninvasive method preferable. The purpose of this study was to demonstrate that glucose levels can be measured transdermally with the combination of the low-profile cymbal array and an electrochemical glucose sensor consisting of amperometric electrodes and a novel glucose oxidase hydrogel. Interstitial fluid glucose concentrations can be determined with the electrochemical glucose sensor after the skin is made permeable to glucose by ultrasound (US) (20 kHz) with the thin (< 7 mm) and light (< 22 g) cymbal array. Using this array to deliver insulin into hyperglycemic rats, our previous experiments demonstrated that blood glucose levels would decrease 233.3 mg/dl with 5 min of US exposure. With the sensor and array, our goal was to determine the glucose levels of hyperglycemic rats noninvasively and evaluate the possible bioeffects. A total of 12 anesthetized rats were placed into two groups (US exposure group and control group) and the array (I(SPTP) = 100 mW/cm(2)) with a saline reservoir operating for 20 min was affixed to the abdomen. The array was removed and an electrochemical glucose sensor was placed on the exposed area to determine the glucose concentrations through the skin. Comparison was made using a commercial glucose meter with the blood collected from a jugular vein. The average blood glucose level determined by the sensor was 356.0 +/- 116.6 mg/dl, and the glucose level measured by the commercial glucose meter was 424.8 +/- 59.1 mg/dl. These results supported the use of this novel system consisting of the electrochemical glucose sensor and the cymbal array for glucose monitoring.
Similar articles
-
Short ultrasound exposure times for noninvasive insulin delivery in rats using the lightweight cymbal array.IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Feb;51(2):176-80. IEEE Trans Ultrason Ferroelectr Freq Control. 2004. PMID: 15055807
-
Noninvasive ultrasonic transdermal insulin delivery in rabbits using the light-weight cymbal array.Diabetes Technol Ther. 2004 Dec;6(6):808-15. doi: 10.1089/dia.2004.6.808. Diabetes Technol Ther. 2004. PMID: 15684633
-
Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats.Anal Chim Acta. 2007 Jan 2;581(1):7-12. doi: 10.1016/j.aca.2006.08.016. Epub 2006 Aug 18. Anal Chim Acta. 2007. PMID: 17386418
-
Biosensors for real-time in vivo measurements.Biosens Bioelectron. 2005 Jun 15;20(12):2388-403. doi: 10.1016/j.bios.2004.12.003. Epub 2005 Jan 15. Biosens Bioelectron. 2005. PMID: 15854814 Review.
-
The evolution of commercialized glucose sensors in China.Biosens Bioelectron. 2009 Jan 1;24(5):1083-9. doi: 10.1016/j.bios.2008.08.051. Epub 2008 Sep 10. Biosens Bioelectron. 2009. PMID: 18929476 Review.
Cited by
-
Therapeutic Drug Monitoring of Vancomycin in Dermal Interstitial Fluid Using Dissolving Microneedles.Int J Med Sci. 2016 Mar 16;13(4):271-6. doi: 10.7150/ijms.13601. eCollection 2016. Int J Med Sci. 2016. PMID: 27076783 Free PMC article.
-
Ultrasound mediated transdermal insulin delivery in pigs using a lightweight transducer.Pharm Res. 2007 Jul;24(7):1396-401. doi: 10.1007/s11095-007-9306-4. Epub 2007 Apr 19. Pharm Res. 2007. PMID: 17443398
-
Perspectives on transdermal ultrasound mediated drug delivery.Int J Nanomedicine. 2007;2(4):585-94. Int J Nanomedicine. 2007. PMID: 18203426 Free PMC article. Review.
-
Electrochemical Sensors for Clinic Analysis.Sensors (Basel). 2008 Mar 27;8(4):2043-2081. doi: 10.3390/s8042043. Sensors (Basel). 2008. PMID: 27879810 Free PMC article. Review.
-
Current Advancements in Transdermal Biosensing and Targeted Drug Delivery.Sensors (Basel). 2019 Feb 28;19(5):1028. doi: 10.3390/s19051028. Sensors (Basel). 2019. PMID: 30823435 Free PMC article. Review.
Publication types