Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Sep;20(9):1848-53.
doi: 10.1093/ndt/gfh946. Epub 2005 Jun 21.

Hypertonic glucose-based peritoneal dialysate is associated with higher blood pressure and adverse haemodynamics as compared with icodextrin

Affiliations
Comparative Study

Hypertonic glucose-based peritoneal dialysate is associated with higher blood pressure and adverse haemodynamics as compared with icodextrin

Nicholas M Selby et al. Nephrol Dial Transplant. 2005 Sep.

Abstract

Background: Little is known about the haemodynamic effects of continuous ambulatory peritoneal dialysis (CAPD) despite its widespread use in the management of end-stage renal failure. We undertook a study to delineate the haemodynamic effects of CAPD using glucose-containing fluids (1.36 and 3.86% glucose) and icodextrin.

Methods: Eight CAPD patients were recruited for a prospective crossover study. Patients attended for two investigatory days (in random order). CAPD was carried out using 1.36% followed by 3.86% glucose (buffered with lactate/bicarbonate, Physioneal) on one study day and 1.36% glucose followed by 7.5% icodextrin (Extraneal) on the other day. Dwell times were 150 min. Blood pressure (BP) and a full range of haemodynamic variables including pulse (HR), stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were measured non-invasively using continuous arterial pulse wave analysis.

Results: BP was significantly higher during 3.86% glucose dwells as compared with 1.36% glucose or icodextrin dwells (P<0.0001). TPR during all three dwells was similar; the higher blood pressure was due to an increased HR, SV and, therefore, CO during 3.86% glucose dwells. The higher blood pressure during the 3.86% glucose dwells was present despite the highest ultrafiltration volume and sodium removal.

Conclusion: This study demonstrates large magnitude haemodynamic changes in response to CAPD. In addition to the well-recognized adverse effects on blood glucose and long-term peritoneal membrane viability, CAPD fluids containing high glucose concentrations may also exert undesirable effects on systemic haemodynamics, with potential long-term consequences for patient outcomes.

PubMed Disclaimer

Comment in

  • Icodextrin and haemodynamics.
    Woods HF. Woods HF. Nephrol Dial Transplant. 2006 Mar;21(3):820; author reply 820-1. doi: 10.1093/ndt/gfi261. Epub 2005 Dec 7. Nephrol Dial Transplant. 2006. PMID: 16338942 No abstract available.

Publication types