Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study
- PMID: 15972340
- DOI: 10.1148/radiol.2362040513
Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study
Abstract
Purpose: To evaluate the effect of scanner type and calcium measure on the reproducibility of calcium measurements.
Materials and methods: This investigation was approved by the institutional review boards of each study site and by the Institutional Review Board of the Los Angeles Biomedical Research Institute. Informed consent for scanning and participation was obtained from all participants. The study was Health Insurance Portability and Accountability Act compliant. The Multi-Ethnic Study of Atherosclerosis (MESA) is a multicenter observational study of 6814 participants undergoing demographic, risk factor, and subclinical disease evaluations. Coronary artery calcium was measured by using duplicate CT scans. Three study centers used electron-beam computed tomography (CT), and three used multi-detector row CT. Coronary artery calcium was detected in 3355 participants. Three calcium measurement methods-Agatston score, calcium volume, and interpolated volume score-were evaluated. Mean absolute differences between calcium measures on scans 1 and 2, excluding cases for which both scans had a measure of zero, was modeled by using linear regression to compare reproducibility between scanner types. A repeated measures analysis of variance test was used to compare reproducibility across calcium measures, with mean percentage absolute difference as the outcome measure. Rescan reproducibility in relation to misregistrations, noise, and motion artifacts was also examined. Variables were log transformed to create a more normal distribution.
Results: Concordance for presence of calcium between duplicate scans was high and similar for both electron-beam and multi-detector row CT (96%, kappa = 0.92). Mean absolute difference between calcium scores for the two scans was 15.8 for electron-beam and 16.9 for multi-detector row CT scanners (P = .06). Mean relative differences were 20.1 for Agatston score, 18.3 for calcium volume, and 18.3 for interpolated volume score (P < .01). Reproducibility was lower for scans with versus those without image misregistrations or motion artifacts (P < .01 for both).
Conclusion: Electron-beam and multi-detector row CT scanners have equivalent reproducibility for measuring coronary artery calcium. Calcium volumes and interpolated volume scores are slightly more reproducible than Agatston scores. Reproducibility is lower for scans with misregistrations or motion artifacts.
Similar articles
-
Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT.Radiology. 2004 Feb;230(2):397-402. doi: 10.1148/radiol.2302020901. Radiology. 2004. PMID: 14752183
-
Effect of scanner type on the reproducibility of extracoronary measures of calcification: the multi-ethnic study of atherosclerosis.Acad Radiol. 2007 Sep;14(9):1043-9. doi: 10.1016/j.acra.2007.05.021. Acad Radiol. 2007. PMID: 17707311
-
Measuring coronary calcium on CT images adjusted for attenuation differences.Radiology. 2005 May;235(2):403-14. doi: 10.1148/radiol.2352040515. Radiology. 2005. PMID: 15858082
-
Electron beam CT versus helical CT scans for assessing coronary calcification: current utility and future directions.Am Heart J. 2003 Dec;146(6):969-77. doi: 10.1016/S0002-8703(03)00450-2. Am Heart J. 2003. PMID: 14660987 Review.
-
Coronary artery calcifications: a critical assessment of imaging techniques.Blood Purif. 2007;25(1):115-9. doi: 10.1159/000096409. Epub 2006 Dec 14. Blood Purif. 2007. PMID: 17170548 Review.
Cited by
-
Catalysis in abiotic structured media: an approach to selective synthesis of biopolymers.Cell Mol Life Sci. 2005 Mar;62(5):520-34. doi: 10.1007/s00018-004-4342-2. Cell Mol Life Sci. 2005. PMID: 15747059 Free PMC article. Review.
-
Non-invasive half millimetre 32 detector row computed tomography angiography accurately excludes significant stenoses in patients with advanced coronary artery disease and high calcium scores.Heart. 2006 May;92(5):589-97. doi: 10.1136/hrt.2005.074336. Epub 2005 Oct 26. Heart. 2006. PMID: 16251224 Free PMC article.
-
General Cardiovascular Risk Profile identifies advanced coronary artery calcium and is improved by family history: the multiethnic study of atherosclerosis.Circ Cardiovasc Genet. 2010 Feb;3(1):97-105. doi: 10.1161/CIRCGENETICS.109.894527. Epub 2009 Dec 14. Circ Cardiovasc Genet. 2010. PMID: 20160201 Free PMC article.
-
Genetic mapping of vascular calcified plaque loci on chromosome 16p in European Americans from the diabetes heart study.Ann Hum Genet. 2011 Mar;75(2):222-35. doi: 10.1111/j.1469-1809.2010.00632.x. Ann Hum Genet. 2011. PMID: 21309755 Free PMC article.
-
Role of computed tomography in risk assessment for coronary heart disease.Postgrad Med J. 2006 Oct;82(972):664-71. doi: 10.1136/pgmj.2005.043612. Postgrad Med J. 2006. PMID: 17068277 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Molecular Biology Databases