Abstract
Microbeam radiation therapy (MRT) has the potential to treat infantile brain tumours when other kinds of radiotherapy would be excessively toxic to the developing normal brain. MRT uses extraordinarily high doses of x-rays but provides unusual resistance to radioneurotoxicity, presumably from the migration of endothelial cells from 'valleys' into 'peaks', i.e., into directly irradiated microslices of tissues. We present a novel irradiation geometry which results in a tolerable valley dose for the normal tissue and a decreased peak-to-valley dose ratio (PVDR) in the tumour area by applying an innovative cross-firing technique. We propose an MRT technique to orthogonally crossfire two arrays of parallel, nonintersecting, mutually interspersed microbeams that produces tumouricidal doses with small PVDRs where the arrays meet and tolerable radiation doses to normal tissues between the microbeams proximal and distal to the tumour in the paths of the arrays.
Similar articles
-
Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose.Phys Med Biol. 2009 Nov 7;54(21):6711-24. doi: 10.1088/0031-9155/54/21/017. Epub 2009 Oct 20. Phys Med Biol. 2009. PMID: 19841517
-
Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue.Mutat Res. 2010 Apr-Jun;704(1-3):160-6. doi: 10.1016/j.mrrev.2009.12.003. Epub 2009 Dec 23. Mutat Res. 2010. PMID: 20034592 Review.
-
Response of avian embryonic brain to spatially segmented x-ray microbeams.Cell Mol Biol (Noisy-le-grand). 2001 May;47(3):485-93. Cell Mol Biol (Noisy-le-grand). 2001. PMID: 11441956
-
Microbeam radiation therapy: tissue dose penetration and BANG-gel dosimetry of thick-beams' array interlacing.Eur J Radiol. 2008 Dec;68(3 Suppl):S129-36. doi: 10.1016/j.ejrad.2008.04.055. Epub 2008 Jul 7. Eur J Radiol. 2008. PMID: 18606516
-
Radiotherapy for pediatric brain tumors: when and how.Expert Rev Anticancer Ther. 2007 Dec;7(12 Suppl):S69-77. doi: 10.1586/14737140.7.12s.S69. Expert Rev Anticancer Ther. 2007. PMID: 18076312 Review.
Cited by
-
Sparing of tissue by using micro-slit-beam radiation therapy reduces neurotoxicity compared with broad-beam radiation therapy.J Radiat Res. 2017 Jan;58(1):17-23. doi: 10.1093/jrr/rrw065. Epub 2016 Jul 15. J Radiat Res. 2017. PMID: 27422939 Free PMC article.
-
Reduced side effects by proton microchannel radiotherapy: study in a human skin model.Radiat Environ Biophys. 2013 Mar;52(1):123-33. doi: 10.1007/s00411-012-0450-9. Epub 2012 Dec 28. Radiat Environ Biophys. 2013. PMID: 23271171
-
First Evaluation of Temporal and Spatial Fractionation in Proton Minibeam Radiation Therapy of Glioma-Bearing Rats.Cancers (Basel). 2021 Sep 28;13(19):4865. doi: 10.3390/cancers13194865. Cancers (Basel). 2021. PMID: 34638352 Free PMC article.
-
Synchrotron X ray induced axonal transections in the brain of rats assessed by high-field diffusion tensor imaging tractography.PLoS One. 2014 Feb 5;9(2):e88244. doi: 10.1371/journal.pone.0088244. eCollection 2014. PLoS One. 2014. PMID: 24505446 Free PMC article.
-
The influence of the channel size on the reduction of side effects in microchannel proton therapy.Radiat Environ Biophys. 2015 Aug;54(3):335-42. doi: 10.1007/s00411-015-0600-y. Epub 2015 May 9. Radiat Environ Biophys. 2015. PMID: 25956820
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical