Identification of current density distribution in electrically conducting subject with anisotropic conductivity distribution
- PMID: 15972989
- DOI: 10.1088/0031-9155/50/13/015
Identification of current density distribution in electrically conducting subject with anisotropic conductivity distribution
Abstract
Current density imaging (CDI) is able to visualize a three-dimensional current density distribution J inside an electrically conducting subject caused by an externally applied current. CDI may use a magnetic resonance imaging (MRI) scanner to measure the induced magnetic flux density B and compute J via the Ampere law [Formula: see text]. However, measuring all three components of B = (B(x), B(y), B(z)) has a technical difficulty due to the requirement of orthogonal rotations of the subject inside the MRI scanner. In this work, we propose a new method of reconstructing a current density image using only B(z) data so that we can avoid the subject rotation procedure. The method utilizes an auxiliary injection current to compensate the missing information of B(x) and B(y). The major advantage of the method is its applicability to a subject with an anisotropic conductivity distribution. Numerical experiments show the feasibility of the new technique.
Similar articles
-
Analysis of recoverable current from one component of magnetic flux density in MREIT and MRCDI.Phys Med Biol. 2007 Jun 7;52(11):3001-13. doi: 10.1088/0031-9155/52/11/005. Epub 2007 May 4. Phys Med Biol. 2007. PMID: 17505085
-
Conductivity image reconstruction from defective data in MREIT: numerical simulation and animal experiment.IEEE Trans Med Imaging. 2006 Feb;25(2):168-76. doi: 10.1109/TMI.2005.862150. IEEE Trans Med Imaging. 2006. PMID: 16468451
-
Local harmonic B(z) algorithm with domain decomposition in MREIT: computer simulation study.IEEE Trans Med Imaging. 2008 Dec;27(12):1754-61. doi: 10.1109/TMI.2008.926055. IEEE Trans Med Imaging. 2008. PMID: 19033091
-
Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.Physiol Meas. 2008 Oct;29(10):R1-26. doi: 10.1088/0967-3334/29/10/R01. Epub 2008 Sep 17. Physiol Meas. 2008. PMID: 18799834 Review.
-
Generalized encoding through the use of selective excitation in accelerated parallel MRI.NMR Biomed. 2006 May;19(3):379-92. doi: 10.1002/nbm.1047. NMR Biomed. 2006. PMID: 16705639 Review.
Cited by
-
Magnetic Resonance Current Density Imaging (MR-CDI).Adv Exp Med Biol. 2022;1380:135-155. doi: 10.1007/978-3-031-03873-0_6. Adv Exp Med Biol. 2022. PMID: 36306097
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical