Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Dec;56(3):413-7.
doi: 10.1016/j.ejrad.2005.05.011. Epub 2005 Jun 22.

Dose reduction in maxillofacial imaging using low dose Cone Beam CT

Affiliations

Dose reduction in maxillofacial imaging using low dose Cone Beam CT

Kostas Tsiklakis et al. Eur J Radiol. 2005 Dec.

Abstract

Objectives: (a) To measure the absorbed dose at certain anatomical sites of a RANDO phantom and to estimate the effective dose in radiographic imaging of the jaws using low dose Cone Beam computed tomography (CBCT) and (b) to compare the absorbed and the effective doses between thyroid and cervical spine shielding and non-shielding techniques.

Study design: Thermoluminescent dosimeters (TLD-100) were placed at 14 sites in a RANDO phantom, using a Cone Beam CT device (Newtom, Model QR-DVT 9000, Verona, Italy). Dosimetry was carried out applying two techniques: in the first, there was no shielding device used while in the second one, a shielding device (EUREKA!, TRIX) was applied for protection of the thyroid gland and the cervical spine. Effective dose was estimated according to ICRP(60) report (E(ICRP)). An additional estimation of the effective dose was accomplished including the doses of the salivary glands (E(SAL)). A Wilcoxon Signed Ranks Test was used for statistical analysis.

Results: In the non-shielding technique the absorbed doses ranged from 0.16 to 1.67 mGy, while 0.32 and 1.28 mGy were the doses to the thyroid and the cervical spine, respectively. The effective dose, E(ICRP), was 0.035 mSv and the E(SAL) was 0.064 mSv. In the shielding technique, the absorbed doses ranged from 0.09 to 1.64 mGy, while 0.18 and 0.95 mGy were the respective values for the thyroid and the cervical spine. The effective dose, E(ICRP), was 0.023 mSv and E(SAL) was 0.052 mSv.

Conclusions: The use of CBCT for maxillofacial imaging results in a reduced absorbed and effective dose. The use of lead shielding leads to a further reduction of the absorbed doses of thyroid and cervical spine, as well as the effective dose.

PubMed Disclaimer

MeSH terms

LinkOut - more resources