Thinning rate of the precorneal and prelens tear films
- PMID: 15980222
- DOI: 10.1167/iovs.05-0094
Thinning rate of the precorneal and prelens tear films
Abstract
Purpose: To apply interferometry as an in vivo measure of tear film thinning between blinks.
Methods: Wavelength-dependent interference was used to measure the tear film thinning rates in 20 normal contact lens wearers, and spectra were captured at a rate of 4.5 per second for 20 seconds. Four recordings of precorneal tear film (PCTF) thinning were made, followed by 1 hour of hydrogel lens wear and then four recordings of prelens tear film (PLTF) thinning. Subjects were asked to blink 1 second after the beginning of the recording and then hold their eyes open for an additional 19 seconds, followed by 2 minutes of rest between recordings.
Results: The average thinning rate of the PLTF was greater than that of the PCTF and average initial tear film thickness of the PLTF was less than that of the PCTF. For both these reasons, the "tear thinning time" (time to reach 0 thickness) was typically shorter for the PLTF than for the PCTF. Histograms of PCTF and PLTF thinning rates showed a narrow peak corresponding to slow thinning of approximately 1 microm/min, but also many examples of rapid thinning of approximately 10 microm/min, with greater variability. Both the initial thickness and thinning rate of the PLTF correlated with corresponding values for the PCTF, although many more rapidly changing values were associated with the PLTF. Plots of rapid thinning of PCTF and PLTF were both linear and were not accompanied by any significant increase in thickness of corneal epithelium or contact lens, respectively.
Conclusions: Tear film thinning can be analyzed in terms of flow in three spatial directions: (1) outward (evaporation), (2) inward (into the epithelium or contact lens), and (3) parallel to the tear film surface. The results indicate that the second mechanism may be unimportant. Studies have shown a range of tear film evaporation rates from 0.24 to 1.45 microm/min, whereas, when the lipid layer is washed away from the tear film, the thinning rate, due to evaporation, would be approximately 7 microm/min. Thus, slow thinning rates may be due to tear film evaporation, whereas rapid rates (which are often greater than 7 microm/min) presumably include other mechanisms such as dewetting, Marangoni flow (i.e., surface tension gradients), and pressure-gradient flow.
Similar articles
-
The contribution of lipid layer movement to tear film thinning and breakup.Invest Ophthalmol Vis Sci. 2009 Jun;50(6):2747-56. doi: 10.1167/iovs.08-2459. Epub 2009 Feb 14. Invest Ophthalmol Vis Sci. 2009. PMID: 19218611
-
The thickness of the human precorneal tear film: evidence from reflection spectra.Invest Ophthalmol Vis Sci. 2000 Oct;41(11):3348-59. Invest Ophthalmol Vis Sci. 2000. PMID: 11006224
-
The impact of hydrogel lens settling on the thickness of the tears and contact lens.Invest Ophthalmol Vis Sci. 2004 Aug;45(8):2549-54. doi: 10.1167/iovs.04-0149. Invest Ophthalmol Vis Sci. 2004. PMID: 15277476
-
Contributions of evaporation and other mechanisms to tear film thinning and break-up.Optom Vis Sci. 2008 Aug;85(8):623-30. doi: 10.1097/OPX.0b013e318181ae60. Optom Vis Sci. 2008. PMID: 18677230 Review.
-
Incomplete blinking: exposure keratopathy, lid wiper epitheliopathy, dry eye, refractive surgery, and dry contact lenses.Cont Lens Anterior Eye. 2007 Mar;30(1):37-51. doi: 10.1016/j.clae.2006.12.002. Epub 2007 Jan 23. Cont Lens Anterior Eye. 2007. PMID: 17251052 Review.
Cited by
-
Visualization of the precorneal tear film using ultrahigh resolution optical coherence tomography in dry eye.Eye Contact Lens. 2012 Jul;38(4):240-4. doi: 10.1097/ICL.0b013e318257a108. Eye Contact Lens. 2012. PMID: 22735625 Free PMC article.
-
Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.Invest Ophthalmol Vis Sci. 2010 Apr;51(4):1988-93. doi: 10.1167/iovs.09-4389. Epub 2009 Nov 20. Invest Ophthalmol Vis Sci. 2010. PMID: 19933178 Free PMC article.
-
Tear exchange and contact lenses: a review.J Optom. 2015 Jan-Mar;8(1):2-11. doi: 10.1016/j.optom.2014.12.001. Epub 2015 Jan 7. J Optom. 2015. PMID: 25575892 Free PMC article. Review.
-
Emphasis on heat strain to the ocular surface: A functional and clinical study of a modified goggle.Front Public Health. 2022 Aug 2;10:955443. doi: 10.3389/fpubh.2022.955443. eCollection 2022. Front Public Health. 2022. PMID: 35983364 Free PMC article.
-
Effects of wearing swimming goggles on non-invasive tear break-up time in a laboratory setting.J Optom. 2022 Apr-Jun;15(2):154-159. doi: 10.1016/j.optom.2020.09.003. Epub 2021 Jan 19. J Optom. 2022. PMID: 33478924 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical