Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Jul;85(7):656-64.

Navicular drop measurement in people with rheumatoid arthritis: interrater and intrarater reliability

Affiliations
  • PMID: 15982172
Clinical Trial

Navicular drop measurement in people with rheumatoid arthritis: interrater and intrarater reliability

Joseph A Shrader et al. Phys Ther. 2005 Jul.

Abstract

Background and purpose: Navicular drop (ND) measurement may be a valuable examination technique for patients with rheumatoid arthritis (RA). However, no data exist on reliability for this technique in patients with RA. The purposes of this study were: (1) to determine interrater and intrarater reliability of ND measurements in people with RA, (2) to compare ND values of people with RA with published normative data, and (3) to investigate ND measurement error associated with the use of skin markings.

Subjects: Ten women (20 feet) with RA consented to participate.

Methods: Patients completed demographic and function questionnaires. Navicular height (NH) measurements were taken by 2 physical therapists and 1 physical therapist student, following four 1-hour training sessions, using standardized methods and a digital height gauge. Four different NH measurements were taken 3 times on each foot by each of the 3 examiners during a morning session and then repeated during an afternoon session on the same day. Navicular drop values were calculated, including ND1 (as reported in the literature), ND2 (compensating for skin error), and ND3 (single-limb stance). Intraclass correlation coefficients (ICCs) and standard errors of measurement (SEMs) were used to establish reliability.

Results: Means (+/-SD) for each ND measure for sessions 1 and 2, respectively, were as follows: ND1=8.36+/-5.29 mm and 8.29+/-5.24 mm, ND2=9.95+/-5.44 mm and 9.57+/-5.37 mm. The ICCs (2,1 and 2,k, respectively) for all interrater measurements ranged from .67 to .92 (SEM=2.0-3.3 mm) and from .85 to .97 (SEM=1.1-2.0 mm). The ICCs (2,1 and 2,k, respectively) for intrarater measurements ranged from .73 to .95 (SEM=1.3-2.8 mm) and from .90 to .98 (SEM=0.7-1.6 mm). Paired t tests showed the means of ND1 and ND2 for each examiner and for both sessions were significantly different.

Discussion and conclusion: The results suggest that ND measurements for people with RA can be taken reliably by clinicians with varied experience. The ND values for our subjects were slightly greater than reported normal values of 6 to 8 mm. Error associated with skin markings was statistically significant for all sessions and examiners.

PubMed Disclaimer

Publication types

LinkOut - more resources