Abstract
Functional separation of the lungs may be accomplished by several methods. Patient with restricted mouth opening has limited options for one-lung ventilation. We report the use of wire-guided endobronchial blockade, a new tool for achieving one-lung ventilation in a patient with restricted mouth opening requiring nasotracheal, fiberoptic intubation for esophagectomy and reconstruction with gastric tube substitution.