[Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design]

[Article in German]
Affiliations
Comparative Study

[Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design]

[Article in German]
T M Rabsilber et al. Ophthalmologe. 2006 Jan.

Abstract

Background: At the Department of Ophthalmology, Heidelberg, Germany, posterior capsule opacification (PCO) of a silicone and an acrylic intraocular lens (IOL) with a sharp optic edge design was evaluated.

Patients and methods: In a prospective study either the AMO ClariFlex silicone IOL or the Sensar AR40e hydrophobic acrylic IOL were implanted in 47 patients following uneventful phacoemulsification. Mean patient age was 76.2+/-7.8 (ClariFlex) and 73.4+/-12.9 years (AR40e), respectively. The mean follow-up time was 19.7+/-5.34 in the ClariFlex and 21.9+/-1.89 months in the AR40e group. PCO development was evaluated postoperatively using the EPCO 2000 analysis software (scale 0-4). Areas of interest were the total IOL optic, the central 3-mm zone as well as the capsulorhexis.

Results: In both groups, all patients achieved a BCVA of 20/32 (AR40e) and 20/25 (ClariFlex), respectively. There was a very low incidence of PCO development with a mean EPCO score of 0.07+/-0.2 (ClariFlex and 0.15+/-0.2 (AR40e). Within the 3-mm zone and the capsulorhexis, there was a tendency for even lower EPCO scores in both groups. We calculated a statistically significant difference for the two lens materials for all investigated IOL areas (Wilcoxon's test, p<0.05).

Conclusion: Both IOLs with a sharp edge design showed good functional results, a stable position in the capsular bag as well as a low incidence of PCO development. However, the silicone IOL showed statistically significantly lower PCO scores.

PubMed Disclaimer

References

    1. J Cataract Refract Surg. 2004 May;30(5):978-85 - PubMed
    1. J Cataract Refract Surg. 2001 Oct;27(10):1579-85 - PubMed
    1. J Cataract Refract Surg. 2002 Mar;28(3):431-7 - PubMed
    1. J Cataract Refract Surg. 2002 Jul;28(7):1236-40 - PubMed
    1. Eur J Ophthalmol. 2002 May-Jun;12(3):212-8 - PubMed

Publication types

MeSH terms

LinkOut - more resources