Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking
- PMID: 15994054
- DOI: 10.1016/j.orthres.2005.05.002.1100230614
Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking
Abstract
Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out under multiplanar loading representative of normal gait. Five surrogate pertrochanteric fracture specimens with lag screw fixation were loaded up to 20,000 cycles using a biaxial rocking motion (BRM) gait simulation protocol. Another five specimens were loaded using a standard uniaxial loading protocol. The BRM loading group exhibited combined varus collapse (5.4+/-2.9 degrees ) and backward rotation (7.2+/-2.8 degrees ). The uniaxial loading group exhibited four times less varus collapse (1.4+/-1.1 degrees ) as compared to the BRM group, and only negligible rotation. For correlation of lag screw migration in surrogate specimens to that in native bone, six human cadaveric specimens were subjected to BRM loading. The degree of varus collapse (8.5+/-7.7 degrees ) and rotation (7.2+/-6.4 degrees ) in cadaveric specimens were comparable to that in surrogate specimens, with the surrogate specimens showing significantly less variability. The results demonstrate that accounting for clinically realistic multiplanar loading vectors significantly affects implant migration, and therefore should be considered when evaluating the fixation strength of hip screw implants.
Similar articles
-
Development of a test system to analyze different hip fracture osteosyntheses under simulated walking.Biomed Tech (Berl). 2012 Apr;57(2):113-9. doi: 10.1515/bmt-2011-0999. Biomed Tech (Berl). 2012. PMID: 22505494
-
Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.J Orthop Surg Res. 2009 May 18;4:16. doi: 10.1186/1749-799X-4-16. J Orthop Surg Res. 2009. PMID: 19450283 Free PMC article.
-
Comparison of Femoral Head Rotation and Varus Collapse Between a Single Lag Screw and Integrated Dual Screw Intertrochanteric Hip Fracture Fixation Device Using a Cadaveric Hemi-Pelvis Biomechanical Model.J Orthop Trauma. 2016 Apr;30(4):164-9. doi: 10.1097/BOT.0000000000000552. J Orthop Trauma. 2016. PMID: 27003028
-
[Research advance of dynamic hip screw internal fixation in treatment of intertrochanteric fractures].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2005 Oct;19(10):839-42. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2005. PMID: 16274138 Review. Chinese.
-
Are there advances in the treatment of extracapsular hip fractures in the elderly?Injury. 2007 Sep;38 Suppl 3:S77-87. doi: 10.1016/j.injury.2007.08.015. Injury. 2007. PMID: 17723796 Review.
Cited by
-
Factors affect stability of intertrochanteric fractures when elderly patients fall.Biomed J. 2016 Feb;39(1):67-71. doi: 10.1016/j.bj.2015.08.007. Epub 2016 Mar 25. Biomed J. 2016. PMID: 27105600 Free PMC article.
-
Treatment of femoral subtrochanteric fractures with proximal lateral femur locking plates.Acta Ortop Bras. 2012 Dec;20(6):329-33. doi: 10.1590/S1413-78522012000600003. Acta Ortop Bras. 2012. PMID: 24453626 Free PMC article.
-
Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative cases.Eur J Orthop Surg Traumatol. 2020 Feb;30(2):199-205. doi: 10.1007/s00590-019-02557-6. Epub 2019 Sep 20. Eur J Orthop Surg Traumatol. 2020. PMID: 31538272 Review.
-
Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.PLoS One. 2017 Jan 13;12(1):e0170048. doi: 10.1371/journal.pone.0170048. eCollection 2017. PLoS One. 2017. PMID: 28085930 Free PMC article.
-
A randomized, prospective study comparing intertrochanteric hip fracture fixation with the dynamic hip screw and the dynamic helical hip system in a community practice.Iowa Orthop J. 2011;31:166-72. Iowa Orthop J. 2011. PMID: 22096437 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical