Abstract

Background: Contrast-enhanced MR angiography (CE-MRA) using a combined head and neck coil permits non-invasive imaging of the vasculature from the aortic arch through to the Circle of Willis in less than 2 minutes.

Objective: To determine the accuracy of CE-MRA for the detection of vascular pathology, in particular vascular stenoses, using digital subtraction angiography (DSA) as the gold standard.

Methods: In a prospective study of 81 patients referred for DSA, CE-MRA and DSA studies were performed within 72 hours of each other. CE-MRA was performed on a 1.5 Tesla clinical MRI scanner using a five-channel neurovascular array (head and neck coil), with dynamic tracking of the IV gadolinium bolus. CE-MRAs and DSA films were read by two interventional neuroradiologists blinded to the clinical presentation of the patient.

Results: On DSA, there were 77 vascular stenoses > or =50% identified, 51 extracranial and 26 intracranial. The overall sensitivity of CE-MRA using the neurovascular array for the detection of vascular stenoses > or =50% was 57% (95% CI: 46 to 68%) with a specificity of 98% (97 to 99%). The sensitivity for the detection of extracranial vascular stenoses > or =50% was 82% (72 to 93%) with a specificity of 97% (96 to 98%). However, the sensitivity for the detection of intracranial vascular stenoses > or =50% was only 8% (0 to 18%), with a specificity of 99% (98 to 100%).

Conclusions: At this stage Contrast-enhanced MR angiography using a neurovascular coil shows promise as a rapid, specific, and noninvasive screening method for extracranial vascular disease, but not for intracranial vascular disease.