[Hyperpolarized (3)helium gas for functional magnetic resonance imaging of the lung]
- PMID: 16010478
- DOI: 10.1007/s00063-005-1048-7
[Hyperpolarized (3)helium gas for functional magnetic resonance imaging of the lung]
Abstract
Lung imaging is traditionally done using X-ray-based methods, since MRI is limited by low proton density as well as inherent magnetic field inhomogeneities of the lung tissue. After introduction of MRI using hyperpolarized noble gases, a totally new field of MRI of the chest has rapidly evolved. These techniques reveal new functional information of the lungs, which could not be obtained before. The first part of this review describes the underlying MR technology explaining distribution of static ventilation, dynamic distribution of ventilation, lung microstructure (apparent diffusion coefficient [ADC]), measurement of oxygen partial pressure (pO(2)), and safety. The clinical potential is afterwards demonstrated in the second part. Therefore, the effort in normal lungs and the mainly focused diseases chronic obstructive pulmonary disease (COPD), smoker's lung, cystic fibrosis, asthma, lung transplantation, and pulmonary embolism are reported.
Similar articles
-
Functional MRI of the lung using hyperpolarized 3-helium gas.J Magn Reson Imaging. 2004 Oct;20(4):540-54. doi: 10.1002/jmri.20154. J Magn Reson Imaging. 2004. PMID: 15390146 Review.
-
Functional lung imaging using hyperpolarized gas MRI.J Magn Reson Imaging. 2007 May;25(5):910-23. doi: 10.1002/jmri.20876. J Magn Reson Imaging. 2007. PMID: 17410561 Review.
-
[Functional imaging of the lung using a gaseous contrast agent: (3)helium-magnetic resonance imaging].Rofo. 2005 May;177(5):660-9. doi: 10.1055/s-2005-858063. Rofo. 2005. PMID: 15871081 Review. German.
-
[Magnetic resonance tomography with inhalation of polarized noble gases: new perspectives in functional imaging diagnosis of emphysema].Pneumologie. 1998 Oct;52(10):563-7. Pneumologie. 1998. PMID: 9847634 Review. German.
-
[A new method for imaging ventilation-distribution with 3Helium in magnetic resonance tomography].Pneumologie. 1998 May;52(5):286-92. Pneumologie. 1998. PMID: 9654978 German.
Cited by
-
Volumetric dynamic oxygen-enhanced MRI (OE-MRI): comparison with CT Brody score and lung function in cystic fibrosis patients.Eur Radiol. 2018 Oct;28(10):4037-4047. doi: 10.1007/s00330-018-5383-5. Epub 2018 Apr 13. Eur Radiol. 2018. PMID: 29654559
-
Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.Eur Radiol. 2007 May;17(5):1341-51. doi: 10.1007/s00330-006-0422-z. Epub 2006 Sep 30. Eur Radiol. 2007. PMID: 17013593
-
[Functional 3He-MRI of the lungs].Radiologe. 2009 Aug;49(8):720-31. doi: 10.1007/s00117-009-1884-1. Radiologe. 2009. PMID: 19636524 Review. German.
-
3He diffusion MRI in human lungs.J Magn Reson. 2018 Jul;292:90-98. doi: 10.1016/j.jmr.2018.04.007. Epub 2018 Apr 26. J Magn Reson. 2018. PMID: 29705031 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical