New instruments for dry eye diagnosis
- PMID: 16020346
- DOI: 10.1080/08820530590931124
New instruments for dry eye diagnosis
Abstract
Several non-invasive techniques for dry eye diagnosis have been developed in the past decade. These include quantitative assessment of tear volume, tear film stability, tear dynamics, and integrity of ocular surface epithelium. A combination of meniscometry and interferometry is useful for proving focal dry eye, by confirming whether or not tears at the meniscus have an effect on the ocular surface. Interferometer is also useful to evaluate tear dynamics on soft contact lenses. Fluorophotometry is useful for assessing the severity of dry eye from the view point of corneal epithelial barrier function and measuring the tear turnover rate. Both video-meibography and meibometry are useful for screening meibomian gland dysfunction. The advances in these techniques accumulate knowledge regarding pathophysiology of dry eye and allow precise diagnosis of dry eye. More targeted treatment will become feasible based on the clearer pathophysiology.
Similar articles
-
Non-invasive methods of assessing the tear film.Exp Eye Res. 2004 Mar;78(3):399-407. doi: 10.1016/j.exer.2003.09.020. Exp Eye Res. 2004. PMID: 15106919 Review.
-
Strip meniscometry: a new and simple method of tear meniscus evaluation.Invest Ophthalmol Vis Sci. 2006 May;47(5):1895-901. doi: 10.1167/iovs.05-0802. Invest Ophthalmol Vis Sci. 2006. PMID: 16638996 Clinical Trial.
-
An interferometric method for the dynamic evaluation of the tear film.Acta Ophthalmol Scand. 2007 Mar;85(2):202-8. doi: 10.1111/j.1600-0420.2006.00802.x. Acta Ophthalmol Scand. 2007. PMID: 17305735
-
Regional Differences in Tear Film Stability and Meibomian Glands in Patients With Aqueous-Deficient Dry Eye.Eye Contact Lens. 2016 Jul;42(4):250-5. doi: 10.1097/ICL.0000000000000191. Eye Contact Lens. 2016. PMID: 26383772
-
New insights into the morphology and function of meibomian glands.Exp Eye Res. 2017 Oct;163:64-71. doi: 10.1016/j.exer.2017.06.010. Exp Eye Res. 2017. PMID: 28950939 Review.
Cited by
-
Meibography: A review of techniques and technologies.Saudi J Ophthalmol. 2012 Oct;26(4):349-56. doi: 10.1016/j.sjopt.2012.08.007. Saudi J Ophthalmol. 2012. PMID: 23961019 Free PMC article.
-
Corneal Epithelial Immune Dendritic Cell Alterations in Subtypes of Dry Eye Disease: A Pilot In Vivo Confocal Microscopic Study.Invest Ophthalmol Vis Sci. 2015 Nov;56(12):7179-85. doi: 10.1167/iovs.15-17433. Invest Ophthalmol Vis Sci. 2015. PMID: 26540656 Free PMC article. Clinical Trial.
-
Corneal epithelial permeability to fluorescein in humans by a multi-drop method.PLoS One. 2018 Jun 19;13(6):e0198831. doi: 10.1371/journal.pone.0198831. eCollection 2018. PLoS One. 2018. PMID: 29920519 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous