Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Jul;23(4):726-34.
doi: 10.1016/j.orthres.2005.02.006. Epub 2005 Mar 29.

On the influence of soft tissue coverage in the determination of bone kinematics using skin markers

Affiliations
Free article

On the influence of soft tissue coverage in the determination of bone kinematics using skin markers

William R Taylor et al. J Orthop Res. 2005 Jul.
Free article

Abstract

Accurate measurement of underlying bone positions is important for the understanding of normal movement and function, as well as for addressing clinical musculoskeletal or post-injury problems. Non-invasive measurement techniques are limited by the analysis technique and movement of peripheral soft tissues that can introduce significant measurement errors in reproducing the kinematics of the underlying bones when using external skin markers. Reflective markers, skeletally mounted to the right hind limb of three Merino-mix sheep were measured simultaneously with markers attached to the skin of each segment, during repetitions of gait trials. The movement of the skin markers relative to the underlying bone positions was then assessed using the Point Cluster Technique (PCT), raw averaging and the Optimal Common Shape Technique (OCST), a new approach presented in this manuscript. Errors in the position of the proximal joint centre, predicted from the corresponding skin markers, were shown to be phasic and strongly associated with the amount soft tissue coverage, averaging 8.5 mm for the femur, 2.8 for the tibia and 2.0 for the metatarsus. Although the results show a better prediction of bone kinematics associated with the Optimal Common Shape Technique, these errors were large for all three assessment techniques and much greater than the differences between the various techniques. Whilst individual markers moved up to 4 mm from the optimal marker set configuration, average peak errors of up to 16, 5 and 3 mm (hip, knee and tibio-metatarsal joints respectively) were observed, suggesting that a large amount of kinematic noise is produced from the synchronous shifting of marker sets, potentially as a result of underlying muscle firing and the inertial effects of heel impact. Current techniques are therefore limited in their ability to determine the kinematics of underlying bones based on skin markers, particularly in segments with more pronounced soft tissue coverage.

PubMed Disclaimer

Publication types

LinkOut - more resources